{"product_id":"3500-wood-stove-with-blower","title":"3500 Wood Stove With Blower","description":"\u003ch3 class=\"p-head-title\"\u003e3500 Wood Stove With Blower\u003c\/h3\u003e\n\u003cp\u003eSpecifically designed to face the rigor of winter, the Osburn 3500 is an essential for any spacious home, especially in harsh weather conditions. Despite its emissions as 1.6 g\/h, this wood stove utilizes a user-friendly, non-catalytic technology as well as a significant reduction of fuel consumption. The unit features a firebox that can hold up to 50 lb of cordwood, as well as a blower, a thermodisc and an airmate for optimal heat distribution and unparalleled comfort.\u003c\/p\u003e\n\u003cp\u003eA choice of door overlay, a fire screen, a glass ash lip are available as options.\u003c\/p\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TyComb\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eHeating area :\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\"\u003e1,000 - 2,700 Ft\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output :\u003c\/td\u003e\n\u003ctd data-spec-id=\"PWMaSoi\"\u003e110,000 BTU\/h (32.2 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 class=\"h2\"\u003eAppliance performance\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/3500-wood-stove-with-blower\/#note-order-1\" data-target-tab=\"fiche-technique\"\u003e1\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TyComb\" colspan=\"2\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eRecommended heating area-ft² :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/3500-wood-stove-with-blower\/#recommended-maximum\" data-target-tab=\"fiche-technique\"\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\" colspan=\"2\"\u003e1,000 - 2,700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall firebox volume-ft³ :\u003c\/td\u003e\n\u003ctd data-spec-id=\"VolComi\" colspan=\"2\"\u003e3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eEPA loading volume-ft³ :\u003c\/td\u003e\n\u003ctd data-spec-id=\"LoadEPA\" colspan=\"2\"\u003e2.88\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum burn time :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/3500-wood-stove-with-blower\/#recommended-maximum\" data-target-tab=\"fiche-technique\"\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"TempComb\" colspan=\"2\"\u003e10 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output-dry cordwood :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/3500-wood-stove-with-blower\/#note-order-3\" data-target-tab=\"fiche-technique\"\u003e2\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"PWMaSoi\" colspan=\"2\"\u003e110,000 BTU\/h (32.2 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall heat output rate \u0026lt; :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/3500-wood-stove-with-blower\/#note-order-3\" data-target-tab=\"fiche-technique\"\u003e2\u003c\/a\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/3500-wood-stove-with-blower\/#note-order-4\" data-target-tab=\"fiche-technique\"\u003e3\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"PwThMin,PwThMax\" colspan=\"2\"\u003e17,200 BTU\/h (5.0 kW) to 57,800 BTU\/h (16.9 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage overall efficiency (dry cordwood) :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/3500-wood-stove-with-blower\/#note-order-4\" data-target-tab=\"fiche-technique\"\u003e3\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"ReMoyGBmi\"\u003e71 % (HHV)\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/3500-wood-stove-with-blower\/#note-order-5\" data-target-tab=\"fiche-technique\"\u003e4\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"RenMoyGBi\"\u003e76 % (LHV)\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/3500-wood-stove-with-blower\/#note-order-6\" data-target-tab=\"fiche-technique\"\u003e5\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum overall efficiency :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/3500-wood-stove-with-blower\/#note-order-7\" data-target-tab=\"fiche-technique\"\u003e6\u003c\/a\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/3500-wood-stove-with-blower\/#note-order-8\" data-target-tab=\"fiche-technique\"\u003e7\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"EffOpti\" colspan=\"2\"\u003e77 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum heat transfer efficiency :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/3500-wood-stove-with-blower\/#note-order-9\" data-target-tab=\"fiche-technique\"\u003e8\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"RenOTCi\" colspan=\"2\"\u003e75 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage particulate emissions rate :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/3500-wood-stove-with-blower\/#note-order-10\" data-target-tab=\"fiche-technique\"\u003e9\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"Emiss\" colspan=\"2\"\u003e1.6 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage CO :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/3500-wood-stove-with-blower\/#note-order-11\" data-target-tab=\"fiche-technique\"\u003e10\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"TauxCO\" colspan=\"2\"\u003e73 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp id=\"note-order-1\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e1\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eValues are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.\u003c\/p\u003e\n\u003cp id=\"recommended-maximum\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eRecommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.\u003c\/p\u003e\n\u003cp id=\"note-order-3\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e2\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThe maximum heat output (dry cordwood) is based on a loading density varying between 15 lb\/ft³ and 20 lb\/ft³ and reloading intervals ranging from 60 to 120 minutes. Other performances are based on a fuel load prescribed by the standard without any reloading between start and finish. The specified loading density varies between 7 lb\/ft³ and 12 lb\/ft³. The moisture content is between 19% and 25%.\u003c\/p\u003e\n\u003cp id=\"note-order-4\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e3\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eAs measured per CSA B415.1-10 stack loss method.\u003c\/p\u003e\n\u003cp id=\"note-order-5\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e4\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eHigher Heating Value of the fuel.\u003c\/p\u003e\n\u003cp id=\"note-order-6\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e5\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eLower Heating Value of the fuel.\u003c\/p\u003e\n\u003cp id=\"note-order-7\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e6\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ePerformances based on a fuel load prescribed by the standard at 7 lb\/ft³ and with a moisture content between 19% and 25%.\u003c\/p\u003e\n\u003cp id=\"note-order-8\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e7\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eOptimum overall efficiency at a specific burn rate (LHV).\u003c\/p\u003e\n\u003cp id=\"note-order-9\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e8\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThe optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.\u003c\/p\u003e\n\u003cp id=\"note-order-10\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e9\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThis appliance is officially tested and certified by an independent agency.\u003c\/p\u003e\n\u003cp id=\"note-order-11\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e10\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eCarbon monoxyde.\u003c\/p\u003e\n\u003ch3 class=\"h2\"\u003eGeneral features\u003c\/h3\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr data-spec-id=\"Techno\" data-order=\"0\"\u003e\n\u003ctd\u003eCombustion technology\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-catalytic\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"EPA\" data-order=\"26\"\u003e\n\u003ctd\u003eHigh-efficiency certified appliance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes, EPA 2020 approved\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"LongBuci\" data-order=\"33\"\u003e\n\u003ctd\u003eMaximum log length\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e22\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"PosBuch\" data-order=\"34\"\u003e\n\u003ctd\u003eLog positioning\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLoading over width and over depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DiaChei\" data-order=\"35\"\u003e\n\u003ctd\u003eChimney diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DiaEvaci\" data-order=\"36\"\u003e\n\u003ctd\u003eFlue outlet diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyChei\" data-order=\"38\"\u003e\n\u003ctd\u003eType of chimney\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCAN\/ULC S629, UL 103 HT (2100 °F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Hchei\" data-order=\"39\"\u003e\n\u003ctd\u003eMinimum chimney height (feet)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e15'\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Cfeu\" data-order=\"40\"\u003e\n\u003ctd\u003eBaffle type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC-Cast or equivalent\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Alcove\" data-order=\"41\"\u003e\n\u003ctd\u003eApproved for an alcove installation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"MaiMob\" data-order=\"42\"\u003e\n\u003ctd\u003eApproved for a mobile home installation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Poidi\" data-order=\"43\"\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e549 lb (249 kg)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyPorte\" data-order=\"44\"\u003e\n\u003ctd\u003eDoor type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSingle, glass with cast iron frame\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyVitre\" data-order=\"46\"\u003e\n\u003ctd\u003eGlass type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCeramic glass\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"SurfViti\" data-order=\"47\"\u003e\n\u003ctd\u003eGlass surface – dimensions (Width X Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e18 7\/8\" x 11 3\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"AutoCle\" data-order=\"48\"\u003e\n\u003ctd\u003eGlass air-wash system\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyVent\" data-order=\"50\"\u003e\n\u003ctd\u003ePremium quality blower included (CFM)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e130\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimExHHi\" data-order=\"56\"\u003e\n\u003ctd\u003eOverall dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e34 3\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimExHLi\" data-order=\"57\"\u003e\n\u003ctd\u003eOverall dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e28 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimExHPi\" data-order=\"58\"\u003e\n\u003ctd\u003eOverall dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e33 1\/2\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimPorHi\" data-order=\"59\"\u003e\n\u003ctd\u003eDoor opening – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e9 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimPorLi\" data-order=\"60\"\u003e\n\u003ctd\u003eDoor opening - dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e19\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimComHi\" data-order=\"61\"\u003e\n\u003ctd\u003eFirebox – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e12 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimComLi\" data-order=\"62\"\u003e\n\u003ctd\u003eFirebox – dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e22 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimComPi\" data-order=\"63\"\u003e\n\u003ctd\u003eFirebox – dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e20 1\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"BriRef\" data-order=\"64\"\u003e\n\u003ctd\u003eFirebox lined with refractory bricks for better heat distribution\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"SysAirSe\" data-order=\"66\"\u003e\n\u003ctd\u003eStainless-steel secondary-air system improving gas combustion\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"ModSur\" data-order=\"67\"\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePedestal\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"EpAciCi\" data-order=\"69\"\u003e\n\u003ctd\u003eSteel thickness – body\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/16\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"EpAciDi\" data-order=\"70\"\u003e\n\u003ctd\u003eSteel thickness – top\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5\/16\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoEmUs\" data-order=\"126\"\u003e\n\u003ctd\u003eUSA standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEPA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoEmCa\" data-order=\"127\"\u003e\n\u003ctd\u003eCanadian Standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCSA B415.1-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoSeUs\" data-order=\"128\"\u003e\n\u003ctd\u003eUSA standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUL 1482, UL 737\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoSeCa\" data-order=\"129\"\u003e\n\u003ctd\u003eCanadian standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eULC S627\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TestPar\" data-order=\"130\"\u003e\n\u003ctd\u003eTested and listed as per applicable standards\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBy an accredited laboratory (CAN\/USA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Garantie\" data-order=\"131\"\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLimited lifetime\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table-block site-margin no-margin-bottom\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003cspan class=\"bold\"\u003eMinimum clearances to combustibles*\u003c\/span\u003e\u003cbr\u003e\u003cem\u003e(Data expressed in inches. 1 inch = 25.4 mm)\u003c\/em\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\" align=\"center\"\u003eCanada\u003c\/td\u003e\n\u003ctd colspan=\"2\" align=\"center\"\u003eUnited-States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003eSingle wall pipe\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eDouble wall pipe\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eSingle wall pipe\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eDouble wall pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – back wall\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e13 1\/4\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e6\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e13\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance - corner\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e7 1\/4\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e7\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e7 1\/4\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e7\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – side wall\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e14\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e14\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e14\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e14\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – top (measured from the platform on which the appliance is installed)**\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003cp class=\"small\"\u003e* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and\/or web sites).\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003cp class=\"small\"\u003e** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 class=\"h2 no-margin-top\"\u003eGuides\u003c\/h3\u003e\n\u003cp class=\"pdf-list\"\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7668\/46101a_2025-03-31.pdf\" class=\"pdf-list-link\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eOsburn 3500 wood stove install \u0026amp; owner's manual\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(PDF - 6.2 Mo)\u003c\/span\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7515\/46231_ua_2024-09-10.pdf\" class=\"pdf-list-link\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eWood stove manual | Safety notifications \u0026amp; general information\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(PDF - 2.9 Mo)\u003c\/span\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5146\/ob03500-osburn-3500-poele.pdf\" class=\"pdf-list-link\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eOsburn 3500 dimensions\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(PDF - 0.4 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Osburn","offers":[{"title":"Default Title","offer_id":51356642443566,"sku":"OB03500","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0731\/2159\/5694\/files\/ob03500_oa10163_web.jpg?v=1764550819","url":"https:\/\/mhchomecomfort.com\/products\/3500-wood-stove-with-blower","provider":"Fireplace store Mississauga","version":"1.0","type":"link"}