{"title":"Osburn","description":null,"products":[{"product_id":"950-wood-stove","title":"950 Osburn Wood Stove","description":"\u003ch3 class=\"p-head-title\"\u003e950 Wood Stove\u003c\/h3\u003e\n\u003cp\u003eWould you like to add a dose of warmth and cozyness to your home? Bring comfort and functionality to your daily life with the Osburn 950, a small wood stove that will quickly become your cold-season essential.\u003c\/p\u003e\n\u003cp\u003eEquipped with high density bricks, a stainless steel heat shield added to the C-Cast firestop, a top heat deflector to redirect heat in front of the stove as well as side panels that reduce clearances, the Osburn 950 offers quality and performance. Enjoy your winter evenings more than ever before!\u003c\/p\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TyComb\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eHeating area :\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\"\u003e250 - 1,200 Ft\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output :\u003c\/td\u003e\n\u003ctd data-spec-id=\"PWMaSoi\"\u003e45,000 BTU\/h (13.19 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAppliance performance (1)\u003cbr\u003eFuel type :    Dry cordwood (16\" recommended)\u003cbr\u003eRecommended heating area-ft² : ()    250 - 1,200\u003cbr\u003eOverall firebox volume-ft³ :    1.8\u003cbr\u003eEPA loading volume-ft³ :    1.55\u003cbr\u003eMaximum burn time : ()    5 h\u003cbr\u003eMaximum heat output-dry cordwood : (2)    45,000 BTU\/h (13.19 kW)\u003cbr\u003eOverall heat output rate \u0026lt; : (2) (3)    12,124 BTU\/h (3.55 kW) to 26,700 BTU\/h (7.83 kW)\u003cbr\u003eAverage overall efficiency (dry cordwood) : (3)    74 % (HHV) (4)    79 % (LHV) (5)\u003cbr\u003eOptimum overall efficiency : (6) (7)    80 %\u003cbr\u003eOptimum heat transfer efficiency : (8)    79 %\u003cbr\u003eAverage particulate emissions rate : (9)    1.8 g\/h\u003cbr\u003eAverage CO : (10)    74 g\/h\u003cbr\u003e(1) Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.\u003c\/p\u003e\n\u003cp\u003e() Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.\u003c\/p\u003e\n\u003cp\u003e(2) The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb\/ft³ and 20 lb\/ft³ and reloading intervals ranging from 60 to 120 minutes. Other performances are based on a fuel load prescribed by the standard without any reloading between start and finish. The specified loading density varies between 7 lb\/ft³ and 12 lb\/ft³. The moisture content is between 19% and 25%.\u003c\/p\u003e\n\u003cp\u003e(3) As measured per CSA B415.1-10 stack loss method.\u003c\/p\u003e\n\u003cp\u003e(4) Higher Heating Value of the fuel.\u003c\/p\u003e\n\u003cp\u003e(5) Lower Heating Value of the fuel.\u003c\/p\u003e\n\u003cp\u003e(6) Performances based on a fuel load prescribed by the standard at 7 lb\/ft³ and with a moisture content between 19% and 25%.\u003c\/p\u003e\n\u003cp\u003e(7) Optimum overall efficiency at a specific burn rate (LHV).\u003c\/p\u003e\n\u003cp\u003e(8) The optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.\u003c\/p\u003e\n\u003cp\u003e(9) This appliance is officially tested and certified by an independent agency.\u003c\/p\u003e\n\u003cp\u003e(10) Carbon monoxyde.\u003c\/p\u003e\n\u003cp\u003eGeneral features\u003cbr\u003eCombustion technology    Non-catalytic\u003cbr\u003eHigh-efficiency certified appliance    Yes, EPA 2020 approved\u003cbr\u003eMaximum log length    17\"\u003cbr\u003eLog positioning    Loading over depth\u003cbr\u003eChimney diameter    6\"\u003cbr\u003eFlue outlet diameter    6\"\u003cbr\u003eType of chimney    CAN\/ULC S629, UL 103 HT (2100 °F)\u003cbr\u003eMinimum chimney height (feet)    12'\u003cbr\u003eBaffle type    C-Cast or equivalent\u003cbr\u003eApproved for an alcove installation    Yes\u003cbr\u003eApproved for a mobile home installation    Yes\u003cbr\u003eShipping Weight    317 lb (144 kg)\u003cbr\u003eDoor type    Single, glass with cast iron frame\u003cbr\u003eGlass type    Ceramic glass\u003cbr\u003eGlass surface – dimensions (Width X Height)    10 1\/4\" x 8 7\/8\"\u003cbr\u003eGlass air-wash system    Yes\u003cbr\u003eOverall dimension (Height)    28 7\/8''\u003cbr\u003eOverall dimension (Width)    20 1\/4''\u003cbr\u003eOverall dimension (Depth)    27 7\/8''\u003cbr\u003eDoor opening – dimension (Height)    7 5\/8\"\u003cbr\u003eDoor opening - dimension (Width)    12\"\u003cbr\u003eFirebox – dimension (Height)    11 3\/4\"\u003cbr\u003eFirebox – dimension (Width)    14 1\/4\"\u003cbr\u003eFirebox – dimension (Depth)    19 1\/8\"\u003cbr\u003eFirebox lined with refractory bricks for better heat distribution    Yes\u003cbr\u003eStainless-steel secondary-air system improving gas combustion    Yes\u003cbr\u003eSteel thickness – body    3\/16\"\u003cbr\u003eSteel thickness – top    5\/16\"\u003cbr\u003eUSA standard (emissions)    EPA\u003cbr\u003eCanadian Standard (emissions)    CSA B415.1-10\u003cbr\u003eUSA standard (safety)    UL 1482, UL 737\u003cbr\u003eCanadian standard (safety)    ULC S627\u003cbr\u003eTested and listed as per applicable standards    By an accredited laboratory (CAN\/USA)\u003cbr\u003eWarranty    Limited lifetime\u003cbr\u003eMinimum clearances to combustibles*\u003cbr\u003e(Data expressed in inches. 1 inch = 25.4 mm)\u003cbr\u003e     Canada    United-States\u003cbr\u003e     Single wall pipe    Double wall pipe    Single wall pipe    Double wall pipe\u003cbr\u003eClearance – back wall    14\"    6\"    12\"    6\"\u003cbr\u003eClearance - corner    11\"    6\"    11\"    6\"\u003cbr\u003eClearance – side wall    12\"    12\"    12\"    12\"\u003cbr\u003eClearance – top (measured from the platform on which the appliance is installed)**    84\"    84\"    84\"    84\"\u003cbr\u003e* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and\/or web sites).\u003c\/p\u003e\n\u003cp\u003e** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.\u003c\/p\u003e\n\u003ch3 class=\"h2 no-margin-top\"\u003eGuides\u003c\/h3\u003e\n\u003cp class=\"pdf-list\"\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7515\/46231_ua_2024-09-10.pdf\" class=\"pdf-list-link\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eWood stove manual | Safety notifications \u0026amp; general information\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(PDF - 2.9 Mo)\u003c\/span\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/6506\/46262_ia_2022-09-07.pdf\" class=\"pdf-list-link\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eOsburn 950 wood stove installation \u0026amp; operation requirements\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(PDF - 3.7 Mo)\u003c\/span\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/6527\/ob00950.pdf\" class=\"pdf-list-link\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eOsburn 950 dimensions\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(PDF - 0.2 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Osburn","offers":[{"title":"Default Title","offer_id":51356625764654,"sku":"OB00950","price":2249.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0731\/2159\/5694\/files\/Screenshot2025-11-28115313.jpg?v=1764549700"},{"product_id":"950-wood-stove-copy","title":"1700 Osburn Wood Stove","description":"\u003ch3\u003e1700 WOOD STOVE\u003c\/h3\u003e\n\u003cp\u003eDesigned to meet the needs of smaller spaces, the Osburn 1700 combines robustness and elegance to allow you to enjoy your heating experience with confidence. This unit is equipped with high-density bricks, a stainless steel heat shield added to the C-Cast baffle, a cast iron door, a built-in ash pan, a top heat deflector that redirects heat to the front of the unit, and side panels to reduce its clearances.\u003c\/p\u003e\n\u003cp\u003eChoose your favorite version by customizing the unit to suit your style: refined door overlays, new leg designs, glass ash lip; significant innovations for the most seasoned experts. \u003c\/p\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TyComb\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eHeating area :\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\"\u003e500 - 1,800 Ft\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output :\u003c\/td\u003e\n\u003ctd data-spec-id=\"PWMaSoi\"\u003e65,000 BTU\/h (19 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 class=\"h2\"\u003eAppliance performance\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/1700-wood-stove\/#note-order-1\" data-target-tab=\"fiche-technique\"\u003e1\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TyComb\" colspan=\"2\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eRecommended heating area-ft² :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/1700-wood-stove\/#recommended-maximum\" data-target-tab=\"fiche-technique\"\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\" colspan=\"2\"\u003e500 - 1,800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall firebox volume-ft³ :\u003c\/td\u003e\n\u003ctd data-spec-id=\"VolComi\" colspan=\"2\"\u003e1.86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eEPA loading volume-ft³ :\u003c\/td\u003e\n\u003ctd data-spec-id=\"LoadEPA\" colspan=\"2\"\u003e1.44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum burn time :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/1700-wood-stove\/#recommended-maximum\" data-target-tab=\"fiche-technique\"\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"TempComb\" colspan=\"2\"\u003e7 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output-dry cordwood :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/1700-wood-stove\/#note-order-3\" data-target-tab=\"fiche-technique\"\u003e2\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"PWMaSoi\" colspan=\"2\"\u003e65,000 BTU\/h (19 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall heat output rate \u0026lt; :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/1700-wood-stove\/#note-order-3\" data-target-tab=\"fiche-technique\"\u003e2\u003c\/a\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/1700-wood-stove\/#note-order-4\" data-target-tab=\"fiche-technique\"\u003e3\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"PwThMin,PwThMax\" colspan=\"2\"\u003e9,800 BTU\/h (2.87 kW) to 52,200 BTU\/h (15.3 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage overall efficiency (dry cordwood) :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/1700-wood-stove\/#note-order-4\" data-target-tab=\"fiche-technique\"\u003e3\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"ReMoyGBmi\"\u003e68 % (HHV)\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/1700-wood-stove\/#note-order-5\" data-target-tab=\"fiche-technique\"\u003e4\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"RenMoyGBi\"\u003e73 % (LHV)\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/1700-wood-stove\/#note-order-6\" data-target-tab=\"fiche-technique\"\u003e5\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum overall efficiency :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/1700-wood-stove\/#note-order-7\" data-target-tab=\"fiche-technique\"\u003e6\u003c\/a\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/1700-wood-stove\/#note-order-8\" data-target-tab=\"fiche-technique\"\u003e7\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"EffOpti\" colspan=\"2\"\u003e76 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum heat transfer efficiency :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/1700-wood-stove\/#note-order-9\" data-target-tab=\"fiche-technique\"\u003e8\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"RenOTCi\" colspan=\"2\"\u003e75 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage particulate emissions rate :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/1700-wood-stove\/#note-order-10\" data-target-tab=\"fiche-technique\"\u003e9\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"Emiss\" colspan=\"2\"\u003e1.26 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage CO :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/1700-wood-stove\/#note-order-11\" data-target-tab=\"fiche-technique\"\u003e10\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"TauxCO\" colspan=\"2\"\u003e103 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp id=\"note-order-1\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e1\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eValues are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.\u003c\/p\u003e\n\u003cp id=\"recommended-maximum\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eRecommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.\u003c\/p\u003e\n\u003cp id=\"note-order-3\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e2\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThe maximum heat output (dry cordwood) is based on a loading density varying between 15 lb\/ft³ and 20 lb\/ft³ and reloading intervals ranging from 60 to 120 minutes. Other performances are based on a fuel load prescribed by the standard without any reloading between start and finish. The specified loading density varies between 7 lb\/ft³ and 12 lb\/ft³. The moisture content is between 19% and 25%.\u003c\/p\u003e\n\u003cp id=\"note-order-4\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e3\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eAs measured per CSA B415.1-10 stack loss method.\u003c\/p\u003e\n\u003cp id=\"note-order-5\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e4\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eHigher Heating Value of the fuel.\u003c\/p\u003e\n\u003cp id=\"note-order-6\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e5\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eLower Heating Value of the fuel.\u003c\/p\u003e\n\u003cp id=\"note-order-7\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e6\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ePerformances based on a fuel load prescribed by the standard at 7 lb\/ft³ and with a moisture content between 19% and 25%.\u003c\/p\u003e\n\u003cp id=\"note-order-8\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e7\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eOptimum overall efficiency at a specific burn rate (LHV).\u003c\/p\u003e\n\u003cp id=\"note-order-9\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e8\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThe optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.\u003c\/p\u003e\n\u003cp id=\"note-order-10\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e9\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThis appliance is officially tested and certified by an independent agency.\u003c\/p\u003e\n\u003cp id=\"note-order-11\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e10\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eCarbon monoxyde.\u003c\/p\u003e\n\u003ch3 class=\"h2\"\u003eGeneral features\u003c\/h3\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr data-spec-id=\"Techno\" data-order=\"0\"\u003e\n\u003ctd\u003eCombustion technology\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-catalytic\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"EPA\" data-order=\"26\"\u003e\n\u003ctd\u003eHigh-efficiency certified appliance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes, EPA 2020 approved\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"LongBuci\" data-order=\"33\"\u003e\n\u003ctd\u003eMaximum log length\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e18\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"PosBuch\" data-order=\"34\"\u003e\n\u003ctd\u003eLog positioning\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLoading over width\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DiaChei\" data-order=\"35\"\u003e\n\u003ctd\u003eChimney diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DiaEvaci\" data-order=\"36\"\u003e\n\u003ctd\u003eFlue outlet diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyChei\" data-order=\"38\"\u003e\n\u003ctd\u003eType of chimney\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCAN\/ULC S629, UL 103 HT (2100 °F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Hchei\" data-order=\"39\"\u003e\n\u003ctd\u003eMinimum chimney height (feet)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e15'\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Cfeu\" data-order=\"40\"\u003e\n\u003ctd\u003eBaffle type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC-Cast or equivalent\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Alcove\" data-order=\"41\"\u003e\n\u003ctd\u003eApproved for an alcove installation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"MaiMob\" data-order=\"42\"\u003e\n\u003ctd\u003eApproved for a mobile home installation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Poidi\" data-order=\"43\"\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e336 lb (153 kg)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyPorte\" data-order=\"44\"\u003e\n\u003ctd\u003eDoor type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSingle, glass with cast iron frame\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyVitre\" data-order=\"46\"\u003e\n\u003ctd\u003eGlass type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCeramic glass\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"SurfViti\" data-order=\"47\"\u003e\n\u003ctd\u003eGlass surface – dimensions (Width X Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e15 3\/4\" x 9 3\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"AutoCle\" data-order=\"48\"\u003e\n\u003ctd\u003eGlass air-wash system\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimExHHi\" data-order=\"56\"\u003e\n\u003ctd\u003eOverall dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e30 3\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimExHLi\" data-order=\"57\"\u003e\n\u003ctd\u003eOverall dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e24 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimExHPi\" data-order=\"58\"\u003e\n\u003ctd\u003eOverall dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e23 1\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimPorHi\" data-order=\"59\"\u003e\n\u003ctd\u003eDoor opening – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e8 3\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimPorLi\" data-order=\"60\"\u003e\n\u003ctd\u003eDoor opening - dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e17 1\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimComHi\" data-order=\"61\"\u003e\n\u003ctd\u003eFirebox – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e11 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimComLi\" data-order=\"62\"\u003e\n\u003ctd\u003eFirebox – dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e19 5\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimComPi\" data-order=\"63\"\u003e\n\u003ctd\u003eFirebox – dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e13 1\/2\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"BriRef\" data-order=\"64\"\u003e\n\u003ctd\u003eFirebox lined with refractory bricks for better heat distribution\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"SysAirSe\" data-order=\"66\"\u003e\n\u003ctd\u003eStainless-steel secondary-air system improving gas combustion\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"ModSur\" data-order=\"67\"\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLegs or pedestal\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"EpAciCi\" data-order=\"69\"\u003e\n\u003ctd\u003eSteel thickness – body\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/16\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"EpAciDi\" data-order=\"70\"\u003e\n\u003ctd\u003eSteel thickness – top\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5\/16\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoEmUs\" data-order=\"126\"\u003e\n\u003ctd\u003eUSA standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEPA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoEmCa\" data-order=\"127\"\u003e\n\u003ctd\u003eCanadian Standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCSA B415.1-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoSeUs\" data-order=\"128\"\u003e\n\u003ctd\u003eUSA standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUL 1482, UL 737\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoSeCa\" data-order=\"129\"\u003e\n\u003ctd\u003eCanadian standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eULC S627\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TestPar\" data-order=\"130\"\u003e\n\u003ctd\u003eTested and listed as per applicable standards\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBy an accredited laboratory (CAN\/USA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Garantie\" data-order=\"131\"\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLimited lifetime\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table-block site-margin no-margin-bottom\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003cspan class=\"bold\"\u003eMinimum clearances to combustibles*\u003c\/span\u003e\u003cbr\u003e\u003cem\u003e(Data expressed in inches. 1 inch = 25.4 mm)\u003c\/em\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\" align=\"center\"\u003eCanada\u003c\/td\u003e\n\u003ctd colspan=\"2\" align=\"center\"\u003eUnited-States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003eSingle wall pipe\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eDouble wall pipe\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eSingle wall pipe\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eDouble wall pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – back wall\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e14 1\/2\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e6\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e13\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance - corner\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e12\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e6\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e12\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – side wall\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e10\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e10\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e10\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e10\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – top (measured from the platform on which the appliance is installed)**\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – minimum floor protection in front of the appliance\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e18\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e16\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003cp class=\"small\"\u003e* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and\/or web sites).\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003cp class=\"small\"\u003e** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 class=\"h2 no-margin-top\"\u003eGuides\u003c\/h3\u003e\n\u003cp class=\"pdf-list\"\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7515\/46231_ua_2024-09-10.pdf\" class=\"pdf-list-link\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eWood stove manual | Safety notifications \u0026amp; general information\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(PDF - 2.9 Mo)\u003c\/span\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/6992\/45982_ia_2023-09-07.pdf\" class=\"pdf-list-link\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eOsburn 1700 wood stove installation \u0026amp; operation requirements\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(PDF - 8.7 Mo)\u003c\/span\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5143\/ob01700-osburn-1700-poele.pdf\" class=\"pdf-list-link\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eOsburn 1700 dimensions\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(PDF - 0.8 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Osburn","offers":[{"title":"Default Title","offer_id":51356629795118,"sku":"OB01700","price":2849.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0731\/2159\/5694\/files\/ob01700_oa10249_oa10247_web.jpg?v=1764550018"},{"product_id":"2000-wood-stove-with-blower","title":"2000 Wood Stove With Blower","description":"\u003ch3\u003e2000 Wood Stove With Blower\u003c\/h3\u003e\n\u003cp\u003eYear after year, the 2000 model remains one of the most popular wood stoves in the Osburn range.\u003c\/p\u003e\n\u003cp\u003eIn 2018, Osburn redefines the design of this heating appliance and sets new standards for emissions. This new version keeps its 2.4 cubic foot combustion chamber and still offers the same power with an emission performance of around 2.3 g\/h. With this model, the 130 CFM fan is still included; unquestionably the best opportunity this season!\u003c\/p\u003e\n\u003cp\u003eIts new cast iron door gives a youthful look with elegant lines while retaining the spirit of wood heating. Customize your appliance to suit your décor: refined door overlays, new leg designs, glass ash lip with integrated ash pan; significant innovations for the most seasoned experts.\u003c\/p\u003e\n\u003ch3 class=\"h2\"\u003eAppliance performance\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/2000-wood-stove\/#note-order-1\"\u003e1\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"TyComb\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eRecommended heating area-ft² :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/2000-wood-stove\/#recommended-maximum\"\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"Surfi\"\u003e500 - 2,100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall firebox volume-ft³ :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"VolComi\"\u003e2.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eEPA loading volume-ft³ :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"LoadEPA\"\u003e1.95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum burn time :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/2000-wood-stove\/#recommended-maximum\"\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"TempComb\"\u003e8h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output-dry cordwood :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/2000-wood-stove\/#note-order-3\"\u003e2\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"PWMaSoi\"\u003e75,000 BTU\/h (22.0 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall heat output rate \u0026lt; :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/2000-wood-stove\/#note-order-3\"\u003e2\u003c\/a\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/2000-wood-stove\/#note-order-4\"\u003e3\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"PwThMin,PwThMax\"\u003e14,200 BTU\/h (4.16 kW) to 44,500 BTU\/h (13.04 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage overall efficiency (dry cordwood) :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/2000-wood-stove\/#note-order-4\"\u003e3\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"ReMoyGBmi\"\u003e72 % (HHV)\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/2000-wood-stove\/#note-order-5\"\u003e4\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"RenMoyGBi\"\u003e77 % (LHV)\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/2000-wood-stove\/#note-order-6\"\u003e5\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum overall efficiency :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/2000-wood-stove\/#note-order-7\"\u003e6\u003c\/a\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/2000-wood-stove\/#note-order-8\"\u003e7\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"EffOpti\"\u003e79 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum heat transfer efficiency :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/2000-wood-stove\/#note-order-9\"\u003e8\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"RenOTCi\"\u003e76 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage particulate emissions rate :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/2000-wood-stove\/#note-order-10\"\u003e9\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"Emiss\"\u003e2.3 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage CO :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/2000-wood-stove\/#note-order-11\"\u003e10\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"TauxCO\"\u003e69 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"small\" id=\"note-order-1\"\u003e\u003csup\u003e(\u003cstrong\u003e1\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eValues are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"recommended-maximum\"\u003e\u003csup\u003e(\u003cstrong\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eRecommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-3\"\u003e\u003csup\u003e(\u003cstrong\u003e2\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThe maximum heat output (dry cordwood) is based on a loading density varying between 15 lb\/ft³ and 20 lb\/ft³ and reloading intervals ranging from 60 to 120 minutes. Other performances are based on a fuel load prescribed by the standard without any reloading between start and finish. The specified loading density varies between 7 lb\/ft³ and 12 lb\/ft³. The moisture content is between 19% and 25%.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-4\"\u003e\u003csup\u003e(\u003cstrong\u003e3\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eAs measured per CSA B415.1-10 stack loss method.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-5\"\u003e\u003csup\u003e(\u003cstrong\u003e4\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eHigher Heating Value of the fuel.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-6\"\u003e\u003csup\u003e(\u003cstrong\u003e5\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eLower Heating Value of the fuel.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-7\"\u003e\u003csup\u003e(\u003cstrong\u003e6\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ePerformances based on a fuel load prescribed by the standard at 7 lb\/ft³ and with a moisture content between 19% and 25%.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-8\"\u003e\u003csup\u003e(\u003cstrong\u003e7\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eOptimum overall efficiency at a specific burn rate (LHV).\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-9\"\u003e\u003csup\u003e(\u003cstrong\u003e8\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThe optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-10\"\u003e\u003csup\u003e(\u003cstrong\u003e9\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThis appliance is officially tested and certified by an independent agency.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-11\"\u003e\u003csup\u003e(\u003cstrong\u003e10\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eCarbon monoxyde.\u003c\/p\u003e\n\u003ch3 class=\"h2\"\u003eGeneral features\u003c\/h3\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr data-order=\"0\" data-spec-id=\"Techno\"\u003e\n\u003ctd\u003eCombustion technology\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-catalytic\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"26\" data-spec-id=\"EPA\"\u003e\n\u003ctd\u003eHigh-efficiency certified appliance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes, EPA 2020 approved\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"33\" data-spec-id=\"LongBuci\"\u003e\n\u003ctd\u003eMaximum log length\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e20\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"34\" data-spec-id=\"PosBuch\"\u003e\n\u003ctd\u003eLog positioning\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLoading over width\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"35\" data-spec-id=\"DiaChei\"\u003e\n\u003ctd\u003eChimney diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"36\" data-spec-id=\"DiaEvaci\"\u003e\n\u003ctd\u003eFlue outlet diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"38\" data-spec-id=\"TyChei\"\u003e\n\u003ctd\u003eType of chimney\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCAN\/ULC S629, UL 103 HT (2100 °F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"39\" data-spec-id=\"Hchei\"\u003e\n\u003ctd\u003eMinimum chimney height (feet)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e12'\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"40\" data-spec-id=\"Cfeu\"\u003e\n\u003ctd\u003eBaffle type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC-Cast or equivalent\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"41\" data-spec-id=\"Alcove\"\u003e\n\u003ctd\u003eApproved for an alcove installation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"42\" data-spec-id=\"MaiMob\"\u003e\n\u003ctd\u003eApproved for a mobile home installation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"43\" data-spec-id=\"Poidi\"\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e390 lb (177 kg)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"44\" data-spec-id=\"TyPorte\"\u003e\n\u003ctd\u003eDoor type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSingle, glass with cast iron frame\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"46\" data-spec-id=\"TyVitre\"\u003e\n\u003ctd\u003eGlass type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCeramic glass\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"47\" data-spec-id=\"SurfViti\"\u003e\n\u003ctd\u003eGlass surface – dimensions (Width X Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e17 1\/8\" X 10 1\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"48\" data-spec-id=\"AutoCle\"\u003e\n\u003ctd\u003eGlass air-wash system\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"50\" data-spec-id=\"TyVent\"\u003e\n\u003ctd\u003ePremium quality blower included (CFM)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e130\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"56\" data-spec-id=\"DimExHHi\"\u003e\n\u003ctd\u003eOverall dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e33 1\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"57\" data-spec-id=\"DimExHLi\"\u003e\n\u003ctd\u003eOverall dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e27\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"58\" data-spec-id=\"DimExHPi\"\u003e\n\u003ctd\u003eOverall dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e29\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"59\" data-spec-id=\"DimPorHi\"\u003e\n\u003ctd\u003eDoor opening – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e9\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"60\" data-spec-id=\"DimPorLi\"\u003e\n\u003ctd\u003eDoor opening - dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e17 1\/2\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"61\" data-spec-id=\"DimComHi\"\u003e\n\u003ctd\u003eFirebox – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e11 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"62\" data-spec-id=\"DimComLi\"\u003e\n\u003ctd\u003eFirebox – dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e21\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"63\" data-spec-id=\"DimComPi\"\u003e\n\u003ctd\u003eFirebox – dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e16 3\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"64\" data-spec-id=\"BriRef\"\u003e\n\u003ctd\u003eFirebox lined with refractory bricks for better heat distribution\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"66\" data-spec-id=\"SysAirSe\"\u003e\n\u003ctd\u003eStainless-steel secondary-air system improving gas combustion\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"67\" data-spec-id=\"ModSur\"\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLegs or pedestal\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"69\" data-spec-id=\"EpAciCi\"\u003e\n\u003ctd\u003eSteel thickness – body\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/16\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"70\" data-spec-id=\"EpAciDi\"\u003e\n\u003ctd\u003eSteel thickness – top\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5\/16\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"78\" data-spec-id=\"TirCend\"\u003e\n\u003ctd\u003eEasy-to-access ash drawer\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"126\" data-spec-id=\"NoEmUs\"\u003e\n\u003ctd\u003eUSA standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eComply with EPA 2020\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"127\" data-spec-id=\"NoEmCa\"\u003e\n\u003ctd\u003eCanadian Standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCSA B415.1-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"128\" data-spec-id=\"NoSeUs\"\u003e\n\u003ctd\u003eUSA standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUL 1482, UL 737\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"129\" data-spec-id=\"NoSeCa\"\u003e\n\u003ctd\u003eCanadian standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eULC S627\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"130\" data-spec-id=\"TestPar\"\u003e\n\u003ctd\u003eTested and listed as per applicable standards\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBy an accredited laboratory (CAN\/USA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"131\" data-spec-id=\"Garantie\"\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLimited lifetime\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table-block site-margin no-margin-bottom\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003cspan class=\"bold\"\u003eMinimum clearances to combustibles*\u003c\/span\u003e\u003cbr\u003e\u003cem\u003e(Data expressed in inches. 1 inch = 25.4 mm)\u003c\/em\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd align=\"center\" colspan=\"2\"\u003eCanada\u003c\/td\u003e\n\u003ctd align=\"center\" colspan=\"2\"\u003eUnited-States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003eSingle wall pipe\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eDouble wall pipe\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eSingle wall pipe\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eDouble wall pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – back wall\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e14 ½\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e6\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e11\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance - corner\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e10\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e7\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e10\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e7\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – side wall\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e17\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e17\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e16\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – top (measured from the platform on which the appliance is installed)**\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003cp class=\"small\"\u003e* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and\/or web sites).\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003cp class=\"small\"\u003e** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TyComb\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eHeating area :\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\"\u003e500 - 2,100 Ft\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output :\u003c\/td\u003e\n\u003ctd data-spec-id=\"PWMaSoi\"\u003e75,000 BTU\/h (22.0 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 class=\"h2 no-margin-top\"\u003eGuides\u003c\/h3\u003e\n\u003cp class=\"pdf-list\"\u003e\u003ca class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7117\/45926a_2024-03-04.pdf\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eOsburn 2000 wood stove install \u0026amp; owner's manual\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(PDF - 7.0 Mo)\u003c\/span\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7515\/46231_ua_2024-09-10.pdf\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eWood stove manual | Safety notifications \u0026amp; general information\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(PDF - 2.9 Mo)\u003c\/span\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/4355\/ob02015-osburn-2000-poele.pdf\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eOsburn 2000 dimensions\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(PDF - 0.4 Mo)\u003c\/span\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 class=\"h2 no-margin-top\"\u003ePlans \u0026amp; CAD\u003c\/h3\u003e\n\u003cp class=\"pdf-list\"\u003e\u003ca class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/2391\/ob02010-base-cad.dwg\"\u003e\u003cspan class=\"iconfont iconfont-dwg\"\u003e\u003c\/span\u003e2D Diagrams - DWG File - Pedestal\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(DWG - 1.8 Mo)\u003c\/span\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/2393\/ob02010-legs-cad.dwg\"\u003e\u003cspan class=\"iconfont iconfont-dwg\"\u003e\u003c\/span\u003e2D Diagrams - DWG File - Legs\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(DWG - 1.8 Mo)\u003c\/span\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/2392\/ob02010-base-cad.dxf\"\u003e\u003cspan class=\"iconfont iconfont-dxf\"\u003e\u003c\/span\u003e2D Diagrams - DXF File - Pedestal\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(DXF - 6.7 Mo)\u003c\/span\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/2394\/ob02010-legs-cad.dxf\"\u003e\u003cspan class=\"iconfont iconfont-dxf\"\u003e\u003c\/span\u003e2D Diagrams - DXF File - Legs\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(DXF - 6.7 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Osburn","offers":[{"title":"Default Title","offer_id":51356633104686,"sku":"OB02015","price":3449.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0731\/2159\/5694\/files\/ob02015_2000_oa10226_oa10237_web.jpg?v=1764550393"},{"product_id":"3500-wood-stove-with-blower","title":"3500 Osburn Wood Stove With Blower","description":"\u003ch3 class=\"p-head-title\"\u003e3500 Wood Stove With Blower\u003c\/h3\u003e\n\u003cp\u003eSpecifically designed to face the rigor of winter, the Osburn 3500 is an essential for any spacious home, especially in harsh weather conditions. Despite its emissions as 1.6 g\/h, this wood stove utilizes a user-friendly, non-catalytic technology as well as a significant reduction of fuel consumption. The unit features a firebox that can hold up to 50 lb of cordwood, as well as a blower, a thermodisc and an airmate for optimal heat distribution and unparalleled comfort.\u003c\/p\u003e\n\u003cp\u003eA choice of door overlay, a fire screen, a glass ash lip are available as options.\u003c\/p\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TyComb\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eHeating area :\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\"\u003e1,000 - 2,700 Ft\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output :\u003c\/td\u003e\n\u003ctd data-spec-id=\"PWMaSoi\"\u003e110,000 BTU\/h (32.2 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 class=\"h2\"\u003eAppliance performance\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/3500-wood-stove-with-blower\/#note-order-1\" data-target-tab=\"fiche-technique\"\u003e1\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TyComb\" colspan=\"2\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eRecommended heating area-ft² :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/3500-wood-stove-with-blower\/#recommended-maximum\" data-target-tab=\"fiche-technique\"\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\" colspan=\"2\"\u003e1,000 - 2,700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall firebox volume-ft³ :\u003c\/td\u003e\n\u003ctd data-spec-id=\"VolComi\" colspan=\"2\"\u003e3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eEPA loading volume-ft³ :\u003c\/td\u003e\n\u003ctd data-spec-id=\"LoadEPA\" colspan=\"2\"\u003e2.88\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum burn time :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/3500-wood-stove-with-blower\/#recommended-maximum\" data-target-tab=\"fiche-technique\"\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"TempComb\" colspan=\"2\"\u003e10 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output-dry cordwood :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/3500-wood-stove-with-blower\/#note-order-3\" data-target-tab=\"fiche-technique\"\u003e2\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"PWMaSoi\" colspan=\"2\"\u003e110,000 BTU\/h (32.2 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall heat output rate \u0026lt; :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/3500-wood-stove-with-blower\/#note-order-3\" data-target-tab=\"fiche-technique\"\u003e2\u003c\/a\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/3500-wood-stove-with-blower\/#note-order-4\" data-target-tab=\"fiche-technique\"\u003e3\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"PwThMin,PwThMax\" colspan=\"2\"\u003e17,200 BTU\/h (5.0 kW) to 57,800 BTU\/h (16.9 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage overall efficiency (dry cordwood) :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/3500-wood-stove-with-blower\/#note-order-4\" data-target-tab=\"fiche-technique\"\u003e3\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"ReMoyGBmi\"\u003e71 % (HHV)\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/3500-wood-stove-with-blower\/#note-order-5\" data-target-tab=\"fiche-technique\"\u003e4\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"RenMoyGBi\"\u003e76 % (LHV)\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/3500-wood-stove-with-blower\/#note-order-6\" data-target-tab=\"fiche-technique\"\u003e5\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum overall efficiency :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/3500-wood-stove-with-blower\/#note-order-7\" data-target-tab=\"fiche-technique\"\u003e6\u003c\/a\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/3500-wood-stove-with-blower\/#note-order-8\" data-target-tab=\"fiche-technique\"\u003e7\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"EffOpti\" colspan=\"2\"\u003e77 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum heat transfer efficiency :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/3500-wood-stove-with-blower\/#note-order-9\" data-target-tab=\"fiche-technique\"\u003e8\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"RenOTCi\" colspan=\"2\"\u003e75 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage particulate emissions rate :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/3500-wood-stove-with-blower\/#note-order-10\" data-target-tab=\"fiche-technique\"\u003e9\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"Emiss\" colspan=\"2\"\u003e1.6 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage CO :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/3500-wood-stove-with-blower\/#note-order-11\" data-target-tab=\"fiche-technique\"\u003e10\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"TauxCO\" colspan=\"2\"\u003e73 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp id=\"note-order-1\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e1\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eValues are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.\u003c\/p\u003e\n\u003cp id=\"recommended-maximum\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eRecommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.\u003c\/p\u003e\n\u003cp id=\"note-order-3\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e2\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThe maximum heat output (dry cordwood) is based on a loading density varying between 15 lb\/ft³ and 20 lb\/ft³ and reloading intervals ranging from 60 to 120 minutes. Other performances are based on a fuel load prescribed by the standard without any reloading between start and finish. The specified loading density varies between 7 lb\/ft³ and 12 lb\/ft³. The moisture content is between 19% and 25%.\u003c\/p\u003e\n\u003cp id=\"note-order-4\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e3\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eAs measured per CSA B415.1-10 stack loss method.\u003c\/p\u003e\n\u003cp id=\"note-order-5\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e4\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eHigher Heating Value of the fuel.\u003c\/p\u003e\n\u003cp id=\"note-order-6\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e5\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eLower Heating Value of the fuel.\u003c\/p\u003e\n\u003cp id=\"note-order-7\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e6\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ePerformances based on a fuel load prescribed by the standard at 7 lb\/ft³ and with a moisture content between 19% and 25%.\u003c\/p\u003e\n\u003cp id=\"note-order-8\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e7\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eOptimum overall efficiency at a specific burn rate (LHV).\u003c\/p\u003e\n\u003cp id=\"note-order-9\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e8\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThe optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.\u003c\/p\u003e\n\u003cp id=\"note-order-10\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e9\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThis appliance is officially tested and certified by an independent agency.\u003c\/p\u003e\n\u003cp id=\"note-order-11\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e10\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eCarbon monoxyde.\u003c\/p\u003e\n\u003ch3 class=\"h2\"\u003eGeneral features\u003c\/h3\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr data-spec-id=\"Techno\" data-order=\"0\"\u003e\n\u003ctd\u003eCombustion technology\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-catalytic\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"EPA\" data-order=\"26\"\u003e\n\u003ctd\u003eHigh-efficiency certified appliance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes, EPA 2020 approved\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"LongBuci\" data-order=\"33\"\u003e\n\u003ctd\u003eMaximum log length\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e22\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"PosBuch\" data-order=\"34\"\u003e\n\u003ctd\u003eLog positioning\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLoading over width and over depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DiaChei\" data-order=\"35\"\u003e\n\u003ctd\u003eChimney diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DiaEvaci\" data-order=\"36\"\u003e\n\u003ctd\u003eFlue outlet diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyChei\" data-order=\"38\"\u003e\n\u003ctd\u003eType of chimney\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCAN\/ULC S629, UL 103 HT (2100 °F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Hchei\" data-order=\"39\"\u003e\n\u003ctd\u003eMinimum chimney height (feet)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e15'\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Cfeu\" data-order=\"40\"\u003e\n\u003ctd\u003eBaffle type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC-Cast or equivalent\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Alcove\" data-order=\"41\"\u003e\n\u003ctd\u003eApproved for an alcove installation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"MaiMob\" data-order=\"42\"\u003e\n\u003ctd\u003eApproved for a mobile home installation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Poidi\" data-order=\"43\"\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e549 lb (249 kg)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyPorte\" data-order=\"44\"\u003e\n\u003ctd\u003eDoor type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSingle, glass with cast iron frame\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyVitre\" data-order=\"46\"\u003e\n\u003ctd\u003eGlass type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCeramic glass\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"SurfViti\" data-order=\"47\"\u003e\n\u003ctd\u003eGlass surface – dimensions (Width X Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e18 7\/8\" x 11 3\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"AutoCle\" data-order=\"48\"\u003e\n\u003ctd\u003eGlass air-wash system\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyVent\" data-order=\"50\"\u003e\n\u003ctd\u003ePremium quality blower included (CFM)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e130\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimExHHi\" data-order=\"56\"\u003e\n\u003ctd\u003eOverall dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e34 3\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimExHLi\" data-order=\"57\"\u003e\n\u003ctd\u003eOverall dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e28 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimExHPi\" data-order=\"58\"\u003e\n\u003ctd\u003eOverall dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e33 1\/2\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimPorHi\" data-order=\"59\"\u003e\n\u003ctd\u003eDoor opening – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e9 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimPorLi\" data-order=\"60\"\u003e\n\u003ctd\u003eDoor opening - dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e19\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimComHi\" data-order=\"61\"\u003e\n\u003ctd\u003eFirebox – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e12 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimComLi\" data-order=\"62\"\u003e\n\u003ctd\u003eFirebox – dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e22 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimComPi\" data-order=\"63\"\u003e\n\u003ctd\u003eFirebox – dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e20 1\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"BriRef\" data-order=\"64\"\u003e\n\u003ctd\u003eFirebox lined with refractory bricks for better heat distribution\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"SysAirSe\" data-order=\"66\"\u003e\n\u003ctd\u003eStainless-steel secondary-air system improving gas combustion\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"ModSur\" data-order=\"67\"\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePedestal\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"EpAciCi\" data-order=\"69\"\u003e\n\u003ctd\u003eSteel thickness – body\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/16\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"EpAciDi\" data-order=\"70\"\u003e\n\u003ctd\u003eSteel thickness – top\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5\/16\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoEmUs\" data-order=\"126\"\u003e\n\u003ctd\u003eUSA standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEPA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoEmCa\" data-order=\"127\"\u003e\n\u003ctd\u003eCanadian Standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCSA B415.1-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoSeUs\" data-order=\"128\"\u003e\n\u003ctd\u003eUSA standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUL 1482, UL 737\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoSeCa\" data-order=\"129\"\u003e\n\u003ctd\u003eCanadian standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eULC S627\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TestPar\" data-order=\"130\"\u003e\n\u003ctd\u003eTested and listed as per applicable standards\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBy an accredited laboratory (CAN\/USA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Garantie\" data-order=\"131\"\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLimited lifetime\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table-block site-margin no-margin-bottom\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003cspan class=\"bold\"\u003eMinimum clearances to combustibles*\u003c\/span\u003e\u003cbr\u003e\u003cem\u003e(Data expressed in inches. 1 inch = 25.4 mm)\u003c\/em\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\" align=\"center\"\u003eCanada\u003c\/td\u003e\n\u003ctd colspan=\"2\" align=\"center\"\u003eUnited-States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003eSingle wall pipe\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eDouble wall pipe\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eSingle wall pipe\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eDouble wall pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – back wall\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e13 1\/4\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e6\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e13\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance - corner\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e7 1\/4\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e7\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e7 1\/4\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e7\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – side wall\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e14\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e14\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e14\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e14\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – top (measured from the platform on which the appliance is installed)**\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003cp class=\"small\"\u003e* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and\/or web sites).\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003cp class=\"small\"\u003e** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 class=\"h2 no-margin-top\"\u003eGuides\u003c\/h3\u003e\n\u003cp class=\"pdf-list\"\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7668\/46101a_2025-03-31.pdf\" class=\"pdf-list-link\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eOsburn 3500 wood stove install \u0026amp; owner's manual\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(PDF - 6.2 Mo)\u003c\/span\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7515\/46231_ua_2024-09-10.pdf\" class=\"pdf-list-link\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eWood stove manual | Safety notifications \u0026amp; general information\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(PDF - 2.9 Mo)\u003c\/span\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5146\/ob03500-osburn-3500-poele.pdf\" class=\"pdf-list-link\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eOsburn 3500 dimensions\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(PDF - 0.4 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Osburn","offers":[{"title":"Default Title","offer_id":51356642443566,"sku":"OB03500","price":4199.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0731\/2159\/5694\/files\/ob03500_oa10163_web.jpg?v=1764550819"},{"product_id":"inspire-2000-wood-stove","title":"INSPIRE 2000 Wood Stove","description":"\u003ch3\u003eINSPIRE 2000 Wood Stove\u003c\/h3\u003e\n\u003cp\u003eAre you interested in getting off the beaten path? The Inspire offers a style that will surely withstand variable trends with these pure lines of balanced proportions, allowing the brand  Osburn to easily compare to European-style products. This more contemporary look is available on steel base, soapstone or even a minimalist base for those who prefer to place the unit directly on a non-combustible podium. Equipped with a 2.3 cubic feet firebox and an outside air intake, this unit will meet the requirements of domestic energy standards, not to mention that a mobile home installation is permitted.\u003c\/p\u003e\n\u003cp\u003e The Inspire meets EPA requirements with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eemissions as 2.3 g\/h\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand complies with the most stringent North American requirements. A guarantee of quality, reliability and durability, once again Osburn clearly demonstrates its firm commitment to the environment to the delight of wood heating fans.\u003c\/p\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TyComb\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eHeating area :\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\"\u003e500 - 2,100 Ft\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output :\u003c\/td\u003e\n\u003ctd data-spec-id=\"PWMaSoi\"\u003e75,000 BTU\/h (22.0 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 class=\"h2\"\u003eAppliance performance\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/inspire-wood-stove\/#note-order-1\" data-target-tab=\"fiche-technique\"\u003e1\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TyComb\" colspan=\"2\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eRecommended heating area-ft² :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/inspire-wood-stove\/#recommended-maximum\" data-target-tab=\"fiche-technique\"\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\" colspan=\"2\"\u003e500 - 2,100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall firebox volume-ft³ :\u003c\/td\u003e\n\u003ctd data-spec-id=\"VolComi\" colspan=\"2\"\u003e2.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eEPA loading volume-ft³ :\u003c\/td\u003e\n\u003ctd data-spec-id=\"LoadEPA\" colspan=\"2\"\u003e1.95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum burn time :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/inspire-wood-stove\/#recommended-maximum\" data-target-tab=\"fiche-technique\"\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"TempComb\" colspan=\"2\"\u003e8 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output-dry cordwood :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/inspire-wood-stove\/#note-order-3\" data-target-tab=\"fiche-technique\"\u003e2\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"PWMaSoi\" colspan=\"2\"\u003e75,000 BTU\/h (22.0 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall heat output rate \u0026lt; :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/inspire-wood-stove\/#note-order-3\" data-target-tab=\"fiche-technique\"\u003e2\u003c\/a\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/inspire-wood-stove\/#note-order-4\" data-target-tab=\"fiche-technique\"\u003e3\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"PwThMin,PwThMax\" colspan=\"2\"\u003e14,200 BTU\/h (4.16 kW) to 44,500 BTU\/h (13.04 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage overall efficiency (dry cordwood) :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/inspire-wood-stove\/#note-order-4\" data-target-tab=\"fiche-technique\"\u003e3\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"ReMoyGBmi\"\u003e72 % (HHV)\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/inspire-wood-stove\/#note-order-5\" data-target-tab=\"fiche-technique\"\u003e4\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"RenMoyGBi\"\u003e77 % (LHV)\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/inspire-wood-stove\/#note-order-6\" data-target-tab=\"fiche-technique\"\u003e5\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum overall efficiency :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/inspire-wood-stove\/#note-order-7\" data-target-tab=\"fiche-technique\"\u003e6\u003c\/a\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/inspire-wood-stove\/#note-order-8\" data-target-tab=\"fiche-technique\"\u003e7\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"EffOpti\" colspan=\"2\"\u003e79 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum heat transfer efficiency :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/inspire-wood-stove\/#note-order-9\" data-target-tab=\"fiche-technique\"\u003e8\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"RenOTCi\" colspan=\"2\"\u003e76 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage particulate emissions rate :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/inspire-wood-stove\/#note-order-10\" data-target-tab=\"fiche-technique\"\u003e9\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"Emiss\" colspan=\"2\"\u003e2.3 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage CO :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/inspire-wood-stove\/#note-order-11\" data-target-tab=\"fiche-technique\"\u003e10\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"TauxCO\" colspan=\"2\"\u003e69 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp id=\"note-order-1\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e1\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eValues are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.\u003c\/p\u003e\n\u003cp id=\"recommended-maximum\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eRecommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.\u003c\/p\u003e\n\u003cp id=\"note-order-3\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e2\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThe maximum heat output (dry cordwood) is based on a loading density varying between 15 lb\/ft³ and 20 lb\/ft³ and reloading intervals ranging from 60 to 120 minutes. Other performances are based on a fuel load prescribed by the standard without any reloading between start and finish. The specified loading density varies between 7 lb\/ft³ and 12 lb\/ft³. The moisture content is between 19% and 25%.\u003c\/p\u003e\n\u003cp id=\"note-order-4\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e3\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eAs measured per CSA B415.1-10 stack loss method.\u003c\/p\u003e\n\u003cp id=\"note-order-5\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e4\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eHigher Heating Value of the fuel.\u003c\/p\u003e\n\u003cp id=\"note-order-6\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e5\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eLower Heating Value of the fuel.\u003c\/p\u003e\n\u003cp id=\"note-order-7\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e6\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ePerformances based on a fuel load prescribed by the standard at 7 lb\/ft³ and with a moisture content between 19% and 25%.\u003c\/p\u003e\n\u003cp id=\"note-order-8\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e7\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eOptimum overall efficiency at a specific burn rate (LHV).\u003c\/p\u003e\n\u003cp id=\"note-order-9\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e8\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThe optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.\u003c\/p\u003e\n\u003cp id=\"note-order-10\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e9\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThis appliance is officially tested and certified by an independent agency.\u003c\/p\u003e\n\u003cp id=\"note-order-11\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e10\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eCarbon monoxyde.\u003c\/p\u003e\n\u003ch3 class=\"h2\"\u003eGeneral features\u003c\/h3\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr data-spec-id=\"Techno\" data-order=\"0\"\u003e\n\u003ctd\u003eCombustion technology\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-catalytic\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"EPA\" data-order=\"26\"\u003e\n\u003ctd\u003eHigh-efficiency certified appliance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes, EPA 2020 approved\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"LongBuci\" data-order=\"33\"\u003e\n\u003ctd\u003eMaximum log length\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e20\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"PosBuch\" data-order=\"34\"\u003e\n\u003ctd\u003eLog positioning\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLoading over width\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DiaChei\" data-order=\"35\"\u003e\n\u003ctd\u003eChimney diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DiaEvaci\" data-order=\"36\"\u003e\n\u003ctd\u003eFlue outlet diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyChei\" data-order=\"38\"\u003e\n\u003ctd\u003eType of chimney\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCAN\/ULC S629, UL 103 HT (2100 °F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Hchei\" data-order=\"39\"\u003e\n\u003ctd\u003eMinimum chimney height (feet)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e12'\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Cfeu\" data-order=\"40\"\u003e\n\u003ctd\u003eBaffle type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC-Cast or equivalent\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Alcove\" data-order=\"41\"\u003e\n\u003ctd\u003eApproved for an alcove installation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"MaiMob\" data-order=\"42\"\u003e\n\u003ctd\u003eApproved for a mobile home installation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Poidi\" data-order=\"43\"\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e439 lb (199 kg)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyPorte\" data-order=\"44\"\u003e\n\u003ctd\u003eDoor type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSingle, glass with steel frame\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyVitre\" data-order=\"46\"\u003e\n\u003ctd\u003eGlass type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCeramic glass\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"SurfViti\" data-order=\"47\"\u003e\n\u003ctd\u003eGlass surface – dimensions (Width X Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e20 1\/4\" X 9 1\/2\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"AutoCle\" data-order=\"48\"\u003e\n\u003ctd\u003eGlass air-wash system\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimExHHi\" data-order=\"56\"\u003e\n\u003ctd\u003eOverall dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e35 5\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimExHLi\" data-order=\"57\"\u003e\n\u003ctd\u003eOverall dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e27 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimExHPi\" data-order=\"58\"\u003e\n\u003ctd\u003eOverall dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e24 1\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimPorHi\" data-order=\"59\"\u003e\n\u003ctd\u003eDoor opening – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e8 3\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimPorLi\" data-order=\"60\"\u003e\n\u003ctd\u003eDoor opening - dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e20\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimComHi\" data-order=\"61\"\u003e\n\u003ctd\u003eFirebox – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e11 3\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimComLi\" data-order=\"62\"\u003e\n\u003ctd\u003eFirebox – dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e21\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimComPi\" data-order=\"63\"\u003e\n\u003ctd\u003eFirebox – dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e16 3\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"BriRef\" data-order=\"64\"\u003e\n\u003ctd\u003eFirebox lined with refractory bricks for better heat distribution\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"SysAirSe\" data-order=\"66\"\u003e\n\u003ctd\u003eStainless-steel secondary-air system improving gas combustion\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"ModSur\" data-order=\"67\"\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePedestal\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"EpAciCi\" data-order=\"69\"\u003e\n\u003ctd\u003eSteel thickness – body\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/16\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"EpAciDi\" data-order=\"70\"\u003e\n\u003ctd\u003eSteel thickness – top\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5\/16\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TirCend\" data-order=\"78\"\u003e\n\u003ctd\u003eEasy-to-access ash drawer\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoEmUs\" data-order=\"126\"\u003e\n\u003ctd\u003eUSA standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEPA Method 28\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoEmCa\" data-order=\"127\"\u003e\n\u003ctd\u003eCanadian Standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCSA B415.1-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoSeUs\" data-order=\"128\"\u003e\n\u003ctd\u003eUSA standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUL 1482, UL 737\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoSeCa\" data-order=\"129\"\u003e\n\u003ctd\u003eCanadian standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eULC S627\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TestPar\" data-order=\"130\"\u003e\n\u003ctd\u003eTested and listed as per applicable standards\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBy an accredited laboratory (CAN\/USA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Garantie\" data-order=\"131\"\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLimited lifetime\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table-block site-margin no-margin-bottom\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003cspan class=\"bold\"\u003eMinimum clearances to combustibles*\u003c\/span\u003e\u003cbr\u003e\u003cem\u003e(Data expressed in inches. 1 inch = 25.4 mm)\u003c\/em\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\" align=\"center\"\u003eCanada\u003c\/td\u003e\n\u003ctd colspan=\"2\" align=\"center\"\u003eUnited-States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003eSingle wall pipe\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eDouble wall pipe\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eSingle wall pipe\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eDouble wall pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – back wall\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e14 ½\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e6\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e11\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance - corner\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e10\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e7\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e10\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e7\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – side wall\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e17\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e17\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e16\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – top (measured from the platform on which the appliance is installed)**\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003cp class=\"small\"\u003e* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and\/or web sites).\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003cp class=\"small\"\u003e** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 class=\"h2 no-margin-top\"\u003eGuides\u003c\/h3\u003e\n\u003cp class=\"pdf-list\"\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7482\/45951a_2024-09-10.pdf\" class=\"pdf-list-link\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eOsburn Inspire wood stove install \u0026amp; owner's manual\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(PDF - 8.4 Mo)\u003c\/span\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7515\/46231_ua_2024-09-10.pdf\" class=\"pdf-list-link\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eWood stove manual | Safety notifications \u0026amp; general information\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(PDF - 2.9 Mo)\u003c\/span\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/4750\/ob02042_osburn-inspire-2000.pdf\" class=\"pdf-list-link\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eOsburn Inspire dimensions\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(PDF - 1.3 Mo)\u003c\/span\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/4654\/45969af_2021-03-24.pdf\" class=\"pdf-list-link\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eInstallation Instructions - Minimalist Base Kit\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(PDF - 1.6 Mo)\u003c\/span\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/4641\/45966af_2019-03-27.pdf\" class=\"pdf-list-link\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eInstallation Instructions - Steel Base Kit\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(PDF - 1.8 Mo)\u003c\/span\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/4647\/45967af_2019-01-18.pdf\" class=\"pdf-list-link\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eInstallation Instructions - Soapstone Base Kit\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(PDF - 1.8 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Osburn","offers":[{"title":"Default Title","offer_id":51356644999470,"sku":"OB02042","price":4199.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0731\/2159\/5694\/files\/ob02042_inspire_oa10243_web.jpg?v=1764550998"},{"product_id":"matrix-wood-stove-with-blower","title":"MATRIX Wood Stove with Blower","description":"\u003ch3 class=\"p-head-title\"\u003eMATRIX Wood Stove with Blower\u003c\/h3\u003e\n\u003cp\u003eWith the same sleek, modern style and vastly improved performance, the Matrix wood burning stove will certainly bring a European touch to your home. Let the Matrix wood stove provided you the warmth, safety and coziness needed during these cold winters\u003c\/p\u003e\n\u003cp\u003eYou can now personalize your device with the steel or soapstone top and side panel options from a local Quebec City mine, reminding us of the richness of our natural resources. Logs will easily fit under the large firebox, making the Matrix a practical and stylish heater. The Matrix is equipped with a 130 CFM fan to ensure optimal heat distribution. Enjoy the comfort of winter more than ever before!\u003c\/p\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TyComb\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eHeating area :\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\"\u003e500 - 2,100 Ft\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output :\u003c\/td\u003e\n\u003ctd data-spec-id=\"PWMaSoi\"\u003e75,000 BTU\/h (22.0 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 class=\"h2\"\u003eAppliance performance\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/matrix-wood-stove-with-blower\/#note-order-1\"\u003e1\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"TyComb\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eRecommended heating area-ft² :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/matrix-wood-stove-with-blower\/#recommended-maximum\"\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"Surfi\"\u003e500 - 2,100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall firebox volume-ft³ :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"VolComi\"\u003e2.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eEPA loading volume-ft³ :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"LoadEPA\"\u003e1.95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum burn time :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/matrix-wood-stove-with-blower\/#recommended-maximum\"\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"TempComb\"\u003e8 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output-dry cordwood :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/matrix-wood-stove-with-blower\/#note-order-3\"\u003e2\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"PWMaSoi\"\u003e75,000 BTU\/h (22.0 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall heat output rate \u0026lt; :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/matrix-wood-stove-with-blower\/#note-order-3\"\u003e2\u003c\/a\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/matrix-wood-stove-with-blower\/#note-order-4\"\u003e3\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"PwThMin,PwThMax\"\u003e14,200 BTU\/h (4.16 kW) to 44,500 BTU\/h (13.04 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage overall efficiency (dry cordwood) :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/matrix-wood-stove-with-blower\/#note-order-4\"\u003e3\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"ReMoyGBmi\"\u003e72 % (HHV)\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/matrix-wood-stove-with-blower\/#note-order-5\"\u003e4\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"RenMoyGBi\"\u003e77 % (LHV)\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/matrix-wood-stove-with-blower\/#note-order-6\"\u003e5\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum overall efficiency :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/matrix-wood-stove-with-blower\/#note-order-7\"\u003e6\u003c\/a\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/matrix-wood-stove-with-blower\/#note-order-8\"\u003e7\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"EffOpti\"\u003e79 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum heat transfer efficiency :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/matrix-wood-stove-with-blower\/#note-order-9\"\u003e8\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"RenOTCi\"\u003e76 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage particulate emissions rate :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/matrix-wood-stove-with-blower\/#note-order-10\"\u003e9\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"Emiss\"\u003e2.3 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage CO :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-stoves\/matrix-wood-stove-with-blower\/#note-order-11\"\u003e10\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"TauxCO\"\u003e69 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"small\" id=\"note-order-1\"\u003e\u003csup\u003e(\u003cstrong\u003e1\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eValues are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"recommended-maximum\"\u003e\u003csup\u003e(\u003cstrong\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eRecommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-3\"\u003e\u003csup\u003e(\u003cstrong\u003e2\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThe maximum heat output (dry cordwood) is based on a loading density varying between 15 lb\/ft³ and 20 lb\/ft³ and reloading intervals ranging from 60 to 120 minutes. Other performances are based on a fuel load prescribed by the standard without any reloading between start and finish. The specified loading density varies between 7 lb\/ft³ and 12 lb\/ft³. The moisture content is between 19% and 25%.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-4\"\u003e\u003csup\u003e(\u003cstrong\u003e3\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eAs measured per CSA B415.1-10 stack loss method.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-5\"\u003e\u003csup\u003e(\u003cstrong\u003e4\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eHigher Heating Value of the fuel.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-6\"\u003e\u003csup\u003e(\u003cstrong\u003e5\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eLower Heating Value of the fuel.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-7\"\u003e\u003csup\u003e(\u003cstrong\u003e6\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ePerformances based on a fuel load prescribed by the standard at 7 lb\/ft³ and with a moisture content between 19% and 25%.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-8\"\u003e\u003csup\u003e(\u003cstrong\u003e7\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eOptimum overall efficiency at a specific burn rate (LHV).\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-9\"\u003e\u003csup\u003e(\u003cstrong\u003e8\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThe optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-10\"\u003e\u003csup\u003e(\u003cstrong\u003e9\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThis appliance is officially tested and certified by an independent agency.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-11\"\u003e\u003csup\u003e(\u003cstrong\u003e10\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eCarbon monoxyde.\u003c\/p\u003e\n\u003ch3 class=\"h2\"\u003eGeneral features\u003c\/h3\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr data-order=\"0\" data-spec-id=\"Techno\"\u003e\n\u003ctd\u003eCombustion technology\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-catalytic\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"26\" data-spec-id=\"EPA\"\u003e\n\u003ctd\u003eHigh-efficiency certified appliance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes, EPA 2020 approved\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"33\" data-spec-id=\"LongBuci\"\u003e\n\u003ctd\u003eMaximum log length\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e20\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"34\" data-spec-id=\"PosBuch\"\u003e\n\u003ctd\u003eLog positioning\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLoading over width\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"35\" data-spec-id=\"DiaChei\"\u003e\n\u003ctd\u003eChimney diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"36\" data-spec-id=\"DiaEvaci\"\u003e\n\u003ctd\u003eFlue outlet diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"38\" data-spec-id=\"TyChei\"\u003e\n\u003ctd\u003eType of chimney\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCAN\/ULC S629, UL 103 HT (2100 °F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"39\" data-spec-id=\"Hchei\"\u003e\n\u003ctd\u003eMinimum chimney height (feet)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e12'\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"40\" data-spec-id=\"Cfeu\"\u003e\n\u003ctd\u003eBaffle type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC-Cast or equivalent\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"41\" data-spec-id=\"Alcove\"\u003e\n\u003ctd\u003eApproved for an alcove installation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"42\" data-spec-id=\"MaiMob\"\u003e\n\u003ctd\u003eApproved for a mobile home installation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"43\" data-spec-id=\"Poidi\"\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e506 lb (230 kg)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"44\" data-spec-id=\"TyPorte\"\u003e\n\u003ctd\u003eDoor type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSingle, glass with cast iron frame\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"46\" data-spec-id=\"TyVitre\"\u003e\n\u003ctd\u003eGlass type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCeramic glass\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"47\" data-spec-id=\"SurfViti\"\u003e\n\u003ctd\u003eGlass surface – dimensions (Width X Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e19 5\/8\" x 11 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"48\" data-spec-id=\"AutoCle\"\u003e\n\u003ctd\u003eGlass air-wash system\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"50\" data-spec-id=\"TyVent\"\u003e\n\u003ctd\u003ePremium quality blower included (CFM)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e130\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"56\" data-spec-id=\"DimExHHi\"\u003e\n\u003ctd\u003eOverall dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e36 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"57\" data-spec-id=\"DimExHLi\"\u003e\n\u003ctd\u003eOverall dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e27 1\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"58\" data-spec-id=\"DimExHPi\"\u003e\n\u003ctd\u003eOverall dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e25\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"59\" data-spec-id=\"DimPorHi\"\u003e\n\u003ctd\u003eDoor opening – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e8 3\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"60\" data-spec-id=\"DimPorLi\"\u003e\n\u003ctd\u003eDoor opening - dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e17 1\/2\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"61\" data-spec-id=\"DimComHi\"\u003e\n\u003ctd\u003eFirebox – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e11 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"62\" data-spec-id=\"DimComLi\"\u003e\n\u003ctd\u003eFirebox – dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e21\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"63\" data-spec-id=\"DimComPi\"\u003e\n\u003ctd\u003eFirebox – dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e16 1\/2\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"64\" data-spec-id=\"BriRef\"\u003e\n\u003ctd\u003eFirebox lined with refractory bricks for better heat distribution\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"66\" data-spec-id=\"SysAirSe\"\u003e\n\u003ctd\u003eStainless-steel secondary-air system improving gas combustion\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"67\" data-spec-id=\"ModSur\"\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePedestal\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"69\" data-spec-id=\"EpAciCi\"\u003e\n\u003ctd\u003eSteel thickness – body\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/16\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"70\" data-spec-id=\"EpAciDi\"\u003e\n\u003ctd\u003eSteel thickness – top\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5\/16\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"126\" data-spec-id=\"NoEmUs\"\u003e\n\u003ctd\u003eUSA standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEPA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"127\" data-spec-id=\"NoEmCa\"\u003e\n\u003ctd\u003eCanadian Standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCSA B415.1-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"128\" data-spec-id=\"NoSeUs\"\u003e\n\u003ctd\u003eUSA standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUL 1482, UL 737\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"129\" data-spec-id=\"NoSeCa\"\u003e\n\u003ctd\u003eCanadian standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eULC-S627\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"130\" data-spec-id=\"TestPar\"\u003e\n\u003ctd\u003eTested and listed as per applicable standards\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBy an accredited laboratory (CAN\/USA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"131\" data-spec-id=\"Garantie\"\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLimited lifetime\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table-block site-margin no-margin-bottom\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003cspan class=\"bold\"\u003eMinimum clearances to combustibles*\u003c\/span\u003e\u003cbr\u003e\u003cem\u003e(Data expressed in inches. 1 inch = 25.4 mm)\u003c\/em\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd align=\"center\" colspan=\"2\"\u003eCanada\u003c\/td\u003e\n\u003ctd align=\"center\" colspan=\"2\"\u003eUnited-States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003eSingle wall pipe\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eDouble wall pipe\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eSingle wall pipe\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eDouble wall pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – back wall\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e14 1\/2\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e6\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e11\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance - corner\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e10\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e7\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e10\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e7\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – side wall\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e17\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e17\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e16\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – top (measured from the platform on which the appliance is installed)**\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – minimum floor protection in front of the appliance\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e18\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e16\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003cp class=\"small\"\u003e* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and\/or web sites).\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003cp class=\"small\"\u003e** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 class=\"h2 no-margin-top\"\u003eGuides\u003c\/h3\u003e\n\u003cp class=\"pdf-list\"\u003e\u003ca class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7603\/45989a_2024-12-05.pdf\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eOsburn Matrix wood stove install \u0026amp; owner's manual\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(PDF - 7.2 Mo)\u003c\/span\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7515\/46231_ua_2024-09-10.pdf\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eWood stove manual | Safety notifications \u0026amp; general information\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(PDF - 2.9 Mo)\u003c\/span\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5285\/ob02032_matrix-poele.pdf\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eOsburn Matrix dimensions\u003cbr\u003e\u003cspan class=\"pdf-size\"\u003e(PDF - 0.5 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Osburn","offers":[{"title":"Default Title","offer_id":51356647194926,"sku":"OB02032","price":4899.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0731\/2159\/5694\/files\/ob02032_oa10700_oa10704_web.jpg?v=1764551179"},{"product_id":"950-wood-stove-copy-1","title":"1700-I Wood Insert","description":"\u003ch3\u003e1700-I Wood Insert\u003c\/h3\u003e\n\u003cp\u003e\u003cem\u003eWood-burning inserts must only be installed inside an existing masonry fireplace and never in a wooden or combustible structure.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eLike its larger counterpart Osburn 2000, the 1700 insert offers a revamped version of perfect size to provide ambiance and warmth. Give yourself a real haven of peace with an eco-friendly device !\u003c\/p\u003e\n\u003cp\u003eInside and out, this insert is engineered from high quality materials that put you at the center of a heating experience for many years: high-density bricks, stainless steel heat shield added to the C-Cast firestop, cast iron door and quiet blower for increased durability. Discover the different options to customize the look of your appliance, available in black or brushed nickel plated: door overlays, faceplates and faceplate trims.\u003c\/p\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TyComb\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eHeating area :\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\"\u003e500 - 1,800 Ft\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output :\u003c\/td\u003e\n\u003ctd data-spec-id=\"PWMaSoi\"\u003e65,000 BTU\/h (19 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 class=\"h2\"\u003eAppliance performance\u003c\/h4\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TyComb\" colspan=\"2\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eRecommended heating area-ft² :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-inserts\/1700-wood-insert\/#recommended-maximum\" data-target-tab=\"fiche-technique\"\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\" colspan=\"2\"\u003e500 - 1,800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall firebox volume-ft³ :\u003c\/td\u003e\n\u003ctd data-spec-id=\"VolComi\" colspan=\"2\"\u003e1.86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eEPA loading volume-ft³ :\u003c\/td\u003e\n\u003ctd data-spec-id=\"LoadEPA\" colspan=\"2\"\u003e1.44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum burn time :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-inserts\/1700-wood-insert\/#recommended-maximum\" data-target-tab=\"fiche-technique\"\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"TempComb\" colspan=\"2\"\u003e7 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output-dry cordwood :\u003cspan\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"PWMaSoi\" colspan=\"2\"\u003e65,000 BTU\/h (19 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall heat output rate \u0026lt; :\u003cspan\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"PwThMin,PwThMax\" colspan=\"2\"\u003e9,800 BTU\/h (2.87 kW) to 52,200 BTU\/h (15.3 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage overall efficiency (dry cordwood) :\u003c\/td\u003e\n\u003ctd data-spec-id=\"ReMoyGBmi\"\u003e68 % (HHV)\u003c\/td\u003e\n\u003ctd data-spec-id=\"RenMoyGBi\"\u003e73 % (LHV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum overall efficiency :\u003c\/td\u003e\n\u003ctd data-spec-id=\"EffOpti\" colspan=\"2\"\u003e76 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum heat transfer efficiency :\u003c\/td\u003e\n\u003ctd data-spec-id=\"RenOTCi\" colspan=\"2\"\u003e75 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage particulate emissions rate :\u003c\/td\u003e\n\u003ctd data-spec-id=\"Emiss\" colspan=\"2\"\u003e2.4 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage CO :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TauxCO\" colspan=\"2\"\u003e103 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp id=\"note-order-1\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e1\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eValues are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.\u003c\/p\u003e\n\u003cp id=\"recommended-maximum\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eRecommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.\u003c\/p\u003e\n\u003cp id=\"note-order-3\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e2\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThe maximum heat output (dry cordwood) is based on a loading density varying between 15 lb\/ft³ and 20 lb\/ft³ and reloading intervals ranging from 60 to 120 minutes. Other performances are based on a fuel load prescribed by the standard without any reloading between start and finish. The specified loading density varies between 7 lb\/ft³ and 12 lb\/ft³. The moisture content is between 19% and 25%.\u003c\/p\u003e\n\u003cp id=\"note-order-4\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e3\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eAs measured per CSA B415.1-10 stack loss method.\u003c\/p\u003e\n\u003cp id=\"note-order-5\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e4\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eHigher Heating Value of the fuel.\u003c\/p\u003e\n\u003cp id=\"note-order-6\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e5\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eLower Heating Value of the fuel.\u003c\/p\u003e\n\u003cp id=\"note-order-7\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e6\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ePerformances based on a fuel load prescribed by the standard at 7 lb\/ft³ and with a moisture content between 19% and 25%.\u003c\/p\u003e\n\u003cp id=\"note-order-8\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e7\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eOptimum overall efficiency at a specific burn rate (LHV).\u003c\/p\u003e\n\u003cp id=\"note-order-9\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e8\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThe optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.\u003c\/p\u003e\n\u003cp id=\"note-order-10\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e9\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThis appliance is officially tested and certified by an independent agency.\u003c\/p\u003e\n\u003cp id=\"note-order-11\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e10\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eCarbon monoxyde.\u003c\/p\u003e\n\u003ch4 class=\"h2\"\u003eGeneral features\u003c\/h4\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr data-spec-id=\"Techno\" data-order=\"0\"\u003e\n\u003ctd\u003eCombustion technology\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-catalytic\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"EPA\" data-order=\"26\"\u003e\n\u003ctd\u003eHigh-efficiency certified appliance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes, EPA 2020 approved\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"LongBuci\" data-order=\"33\"\u003e\n\u003ctd\u003eMaximum log length\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e18\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"PosBuch\" data-order=\"34\"\u003e\n\u003ctd\u003eLog positioning\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLoading over width\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DiaChei\" data-order=\"35\"\u003e\n\u003ctd\u003eChimney diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DiaEvaci\" data-order=\"36\"\u003e\n\u003ctd\u003eFlue outlet diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyChei\" data-order=\"38\"\u003e\n\u003ctd\u003eType of chimney\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLiner - ULC-S635, CAN\/ULC-S640, UL1777\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Hchei\" data-order=\"39\"\u003e\n\u003ctd\u003eMinimum chimney height (feet)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e15'\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Cfeu\" data-order=\"40\"\u003e\n\u003ctd\u003eBaffle type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC-Cast or equivalent\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"MaiMob\" data-order=\"42\"\u003e\n\u003ctd\u003eApproved for a mobile home installation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNo\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Poidi\" data-order=\"43\"\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e361 lb (164 kg)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyPorte\" data-order=\"44\"\u003e\n\u003ctd\u003eDoor type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSingle, glass with cast iron frame\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyVitre\" data-order=\"46\"\u003e\n\u003ctd\u003eGlass type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCeramic glass\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"SurfViti\" data-order=\"47\"\u003e\n\u003ctd\u003eGlass surface – dimensions (Width X Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e15 3\/4\" x 9 3\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"AutoCle\" data-order=\"48\"\u003e\n\u003ctd\u003eGlass air-wash system\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyVent\" data-order=\"50\"\u003e\n\u003ctd\u003ePremium quality blower included (CFM)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e144\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimExHHi\" data-order=\"56\"\u003e\n\u003ctd\u003eOverall dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e21 1\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimExHLi\" data-order=\"57\"\u003e\n\u003ctd\u003eOverall dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e27 1\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimExHPi\" data-order=\"58\"\u003e\n\u003ctd\u003eOverall dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e22 3\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimPorHi\" data-order=\"59\"\u003e\n\u003ctd\u003eDoor opening – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e8 3\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimPorLi\" data-order=\"60\"\u003e\n\u003ctd\u003eDoor opening - dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e17 1\/4''\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimComHi\" data-order=\"61\"\u003e\n\u003ctd\u003eFirebox – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e11 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimComLi\" data-order=\"62\"\u003e\n\u003ctd\u003eFirebox – dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e19 5\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimComPi\" data-order=\"63\"\u003e\n\u003ctd\u003eFirebox – dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e13 1\/2\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"BriRef\" data-order=\"64\"\u003e\n\u003ctd\u003eFirebox lined with refractory bricks for better heat distribution\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"SysAirSe\" data-order=\"66\"\u003e\n\u003ctd\u003eStainless-steel secondary-air system improving gas combustion\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Spadj\" data-order=\"67\"\u003e\n\u003ctd\u003eAdjustable threaded legs\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"EpAciCi\" data-order=\"69\"\u003e\n\u003ctd\u003eSteel thickness – body\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/16\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"EpAciDi\" data-order=\"70\"\u003e\n\u003ctd\u003eSteel thickness – top\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5\/16\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"OuvAHi\" data-order=\"83\"\u003e\n\u003ctd\u003eFireplace opening – minimum (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e21 1\/2\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"OuvALi\" data-order=\"84\"\u003e\n\u003ctd\u003eFireplace opening – minimum (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e27 1\/2\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"OuvAPi\" data-order=\"85\"\u003e\n\u003ctd\u003eFireplace opening – minimum (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e12 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoEmUs\" data-order=\"126\"\u003e\n\u003ctd\u003eUSA standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEPA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoEmCa\" data-order=\"127\"\u003e\n\u003ctd\u003eCanadian Standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCSA B415.1-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoSeUs\" data-order=\"128\"\u003e\n\u003ctd\u003eUSA standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUL 1482, UL 737\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoSeCa\" data-order=\"129\"\u003e\n\u003ctd\u003eCanadian standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eULC S628\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TestPar\" data-order=\"130\"\u003e\n\u003ctd\u003eTested and listed as per applicable standards\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBy an accredited laboratory (CAN\/USA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Garantie\" data-order=\"131\"\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLimited lifetime\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table-block site-margin no-margin-bottom\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cspan class=\"bold\"\u003eMinimum clearances to combustibles*\u003c\/span\u003e\u003cbr\u003e\u003cem\u003e(Data expressed in inches. 1 inch = 25.4 mm)\u003c\/em\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd colspan=\"1\" align=\"center\"\u003eCanada\u003c\/td\u003e\n\u003ctd colspan=\"1\" align=\"center\"\u003eUnited-States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – top (measured from the platform on which the appliance is installed)**\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – combustible side mantle to unit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e9\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e9\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – combustible top mantle to unit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e27\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e27\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – combustible side wall to unit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e16\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – minimum floor protection in front of the appliance\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e18\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance - from the top of the unit to the shelf\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e27\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – from the top of the insert to the shelf\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e27\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 class=\"h2 no-margin-top\"\u003eGuides\u003c\/h4\u003e\n\u003cp class=\"pdf-list\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7736\/46235_ua_2025-08-19.pdf\" target=\"_blank\" rel=\"noopener\"\u003eWood insert manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pdf-list\"\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7736\/46235_ua_2025-08-19.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSafety notifications \u0026amp; general information\u003cspan class=\"pdf-size\"\u003e(PDF - 2.5 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pdf-list\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/6998\/45981_ia_2023-09-06.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOsburn 1700 wood insert installation \u0026amp; operation requirements\u003cspan class=\"pdf-size\"\u003e(PDF - 7.2 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pdf-list\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5169\/ob01705-osburn-1700-i.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOsburn 1700 dimensions\u003cspan class=\"pdf-size\"\u003e(PDF - 0.6 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5169\/ob01705-osburn-1700-i.pdf\" class=\"pdf-list-link\"\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4 class=\"h2 no-margin-top\"\u003ePlans \u0026amp; CAD\u003c\/h4\u003e\n\u003cp class=\"pdf-list\"\u003e\u003cspan class=\"iconfont iconfont-stp\"\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5827\/ob01705.dwg\" target=\"_blank\" rel=\"noopener\"\u003e2D Diagrams\u003cspan class=\"pdf-size\"\u003e(DWG - 0.3 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5827\/ob01705.dwg\" class=\"pdf-list-link\"\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pdf-list\"\u003e\u003cspan class=\"iconfont iconfont-stp\"\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5828\/ob01705.dxf\" target=\"_blank\" rel=\"noopener\"\u003e2D Diagrams\u003cspan class=\"pdf-size\"\u003e(DXF - 1.1 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Osburn","offers":[{"title":"Default Title","offer_id":51361675870510,"sku":"OB01705","price":3199.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0731\/2159\/5694\/files\/ob01705_oa10116_oa10122_oa10249_web.jpg?v=1764721690"},{"product_id":"matrix-1900-wood-insert-copy","title":"MATRIX 1900 Wood Insert","description":"\u003ch3\u003eMATRIX 1900 Wood Insert\u003c\/h3\u003e\n\u003cp\u003e\u003cem\u003eWood-burning inserts must only be installed inside an existing masonry fireplace and never in a wooden or combustible structure.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eTreat your family to incomparable comfort with the Matrix 1900 wood-burning insert. Its magnificent cast-iron faceplate is adorned with a patterned upper louver and columns that frame its large door. Its discreet black wooden handle, air control with removable handle as well as flush mount blower disappear to leave room for the delicate details of its faceplate. Its large glass surface highlights a panoramic view of the flames to fully enjoy your moments near the fire.\u003c\/p\u003e\n\u003cp\u003eThe Matrix 1900 is a compact unit that has tapered top and sides for easy installation in smaller hearths. The deep bottom of its combustion chamber allows ash to accumulate and reduces the frequency of cleaning.\u003c\/p\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TyComb\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eHeating area :\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\"\u003e250 - 1,200 Ft\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output :\u003c\/td\u003e\n\u003ctd data-spec-id=\"PWMaSoi\"\u003e45,000 BTU\/h (13.19 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 class=\"h2\"\u003eAppliance performance\u003c\/h4\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"TyComb\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eRecommended heating area-ft² :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-inserts\/matrix-1900-wood-insert\/#recommended-maximum\"\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"Surfi\"\u003e250 - 1,200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall firebox volume-ft³ :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"VolComi\"\u003e1.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eEPA loading volume-ft³ :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"LoadEPA\"\u003e1.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum burn time :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"TempComb\"\u003e7 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output-dry cordwood :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"PWMaSoi\"\u003e45,000 BTU\/h (13.19 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall heat output rate \u0026lt; :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"PwThMin,PwThMax\"\u003e8,471 BTU\/h (2.48 kW) to 31,700 BTU\/h (9.29 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage overall efficiency (dry cordwood) :\u003c\/td\u003e\n\u003ctd data-spec-id=\"ReMoyGBmi\"\u003e75 % (HHV)\u003c\/td\u003e\n\u003ctd data-spec-id=\"RenMoyGBi\"\u003e80 % (LHV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum overall efficiency :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"EffOpti\"\u003e82 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum heat transfer efficiency :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"RenOTCi\"\u003e78 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage particulate emissions rate :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"Emiss\"\u003e1.5 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage CO :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"TauxCO\"\u003e34 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"small\" id=\"note-order-1\"\u003e\u003csup\u003e(\u003cstrong\u003e1\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eValues are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"recommended-maximum\"\u003e\u003csup\u003e(\u003cstrong\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eRecommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-3\"\u003e\u003csup\u003e(\u003cstrong\u003e2\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThe maximum heat output (dry cordwood) is based on a loading density varying between 15 lb\/ft³ and 20 lb\/ft³ and reloading intervals ranging from 60 to 120 minutes. Other performances are based on a fuel load prescribed by the standard without any reloading between start and finish. The specified loading density varies between 7 lb\/ft³ and 12 lb\/ft³. The moisture content is between 19% and 25%.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-4\"\u003e\u003csup\u003e(\u003cstrong\u003e3\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eAs measured per CSA B415.1-10 stack loss method.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-5\"\u003e\u003csup\u003e(\u003cstrong\u003e4\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eHigher Heating Value of the fuel.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-6\"\u003e\u003csup\u003e(\u003cstrong\u003e5\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eLower Heating Value of the fuel.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-7\"\u003e\u003csup\u003e(\u003cstrong\u003e6\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ePerformances based on a fuel load prescribed by the standard at 7 lb\/ft³ and with a moisture content between 19% and 25%.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-8\"\u003e\u003csup\u003e(\u003cstrong\u003e7\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eOptimum overall efficiency at a specific burn rate (LHV).\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-9\"\u003e\u003csup\u003e(\u003cstrong\u003e8\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThe optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-10\"\u003e\u003csup\u003e(\u003cstrong\u003e9\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThis appliance is officially tested and certified by an independent agency.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-11\"\u003e\u003csup\u003e(\u003cstrong\u003e10\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eCarbon monoxyde.\u003c\/p\u003e\n\u003ch4 class=\"h2\"\u003eGeneral features\u003c\/h4\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr data-order=\"0\" data-spec-id=\"Techno\"\u003e\n\u003ctd\u003eCombustion technology\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-catalytic\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"26\" data-spec-id=\"EPA\"\u003e\n\u003ctd\u003eHigh-efficiency certified appliance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes, EPA 2020 approved\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"33\" data-spec-id=\"LongBuci\"\u003e\n\u003ctd\u003eMaximum log length\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e17\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"34\" data-spec-id=\"PosBuch\"\u003e\n\u003ctd\u003eLog positioning\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLoading over width\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"35\" data-spec-id=\"DiaChei\"\u003e\n\u003ctd\u003eChimney diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"36\" data-spec-id=\"DiaEvaci\"\u003e\n\u003ctd\u003eFlue outlet diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"38\" data-spec-id=\"TyChei\"\u003e\n\u003ctd\u003eType of chimney\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLiner - ULC-S635, CAN\/ULC-S640, UL1777\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"39\" data-spec-id=\"Hchei\"\u003e\n\u003ctd\u003eMinimum chimney height (feet)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e12'\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"40\" data-spec-id=\"Cfeu\"\u003e\n\u003ctd\u003eBaffle type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC-Cast or equivalent\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"42\" data-spec-id=\"MaiMob\"\u003e\n\u003ctd\u003eApproved for a mobile home installation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNo\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"43\" data-spec-id=\"Poidi\"\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e332 lb (151 kg)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"44\" data-spec-id=\"TyPorte\"\u003e\n\u003ctd\u003eDoor type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSingle, glass with cast iron frame\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"46\" data-spec-id=\"TyVitre\"\u003e\n\u003ctd\u003eGlass type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCeramic glass\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"47\" data-spec-id=\"SurfViti\"\u003e\n\u003ctd\u003eGlass surface – dimensions (Width X Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e18\" X 8 1\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"48\" data-spec-id=\"AutoCle\"\u003e\n\u003ctd\u003eGlass air-wash system\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"50\" data-spec-id=\"TyVent\"\u003e\n\u003ctd\u003ePremium quality blower included (CFM)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e90\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"56\" data-spec-id=\"DimExHHi\"\u003e\n\u003ctd\u003eOverall dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e23 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"57\" data-spec-id=\"DimExHLi\"\u003e\n\u003ctd\u003eOverall dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e36\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"58\" data-spec-id=\"DimExHPi\"\u003e\n\u003ctd\u003eOverall dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e21\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"59\" data-spec-id=\"DimPorHi\"\u003e\n\u003ctd\u003eDoor opening – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"60\" data-spec-id=\"DimPorLi\"\u003e\n\u003ctd\u003eDoor opening - dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e18 1\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"61\" data-spec-id=\"DimComHi\"\u003e\n\u003ctd\u003eFirebox – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e8 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"62\" data-spec-id=\"DimComLi\"\u003e\n\u003ctd\u003eFirebox – dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e16 3\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"63\" data-spec-id=\"DimComPi\"\u003e\n\u003ctd\u003eFirebox – dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e12 3\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"65\" data-spec-id=\"PRefrM\"\u003e\n\u003ctd\u003eMoulded refractory bricks\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"66\" data-spec-id=\"SysAirSe\"\u003e\n\u003ctd\u003eStainless-steel secondary-air system improving gas combustion\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"69\" data-spec-id=\"EpAciCi\"\u003e\n\u003ctd\u003eSteel thickness – body\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/16\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"70\" data-spec-id=\"EpAciDi\"\u003e\n\u003ctd\u003eSteel thickness – top\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/16\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"83\" data-spec-id=\"OuvAHi\"\u003e\n\u003ctd\u003eFireplace opening – minimum (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e19\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"84\" data-spec-id=\"OuvALi\"\u003e\n\u003ctd\u003eFireplace opening – minimum (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e25\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"85\" data-spec-id=\"OuvAPi\"\u003e\n\u003ctd\u003eFireplace opening – minimum (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e15 1\/2\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"126\" data-spec-id=\"NoEmUs\"\u003e\n\u003ctd\u003eUSA standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEPA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"127\" data-spec-id=\"NoEmCa\"\u003e\n\u003ctd\u003eCanadian Standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCSA B415.1-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"128\" data-spec-id=\"NoSeUs\"\u003e\n\u003ctd\u003eUSA standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUL 1482, UL 737\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"129\" data-spec-id=\"NoSeCa\"\u003e\n\u003ctd\u003eCanadian standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eULC S628\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"130\" data-spec-id=\"TestPar\"\u003e\n\u003ctd\u003eTested and listed as per applicable standards\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBy an accredited laboratory (CAN\/USA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"131\" data-spec-id=\"Garantie\"\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLimited lifetime\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table-block site-margin no-margin-bottom\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cspan class=\"bold\"\u003eMinimum clearances to combustibles*\u003c\/span\u003e\u003cbr\u003e\u003cem\u003e(Data expressed in inches. 1 inch = 25.4 mm)\u003c\/em\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd align=\"center\" colspan=\"1\"\u003eCanada\u003c\/td\u003e\n\u003ctd align=\"center\" colspan=\"1\"\u003eUnited-States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – top (measured from the platform on which the appliance is installed)**\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e72\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e72\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – combustible side mantle to unit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e1\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – combustible top mantle to unit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e34\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e34\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – combustible side wall to unit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e16\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance - from the shelf to the base of the fireplace\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e34\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e34\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 class=\"h2 no-margin-top\"\u003eGuides\u003c\/h4\u003e\n\u003cp class=\"pdf-list\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003e\u003ca rel=\"noopener\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7748\/46235_ua_2025-08-19.pdf\" target=\"_blank\"\u003eWood insert manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pdf-list\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7748\/46235_ua_2025-08-19.pdf\" target=\"_blank\"\u003eSafety notifications \u0026amp; general information\u003cspan class=\"pdf-size\"\u003e(PDF - 2.5 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7748\/46235_ua_2025-08-19.pdf\"\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/6953\/46278a_2023-05-26.pdf\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pdf-list\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/6953\/46278a_2023-05-26.pdf\" target=\"_blank\"\u003eInstallation \u0026amp; Operation Requirements\u003cspan class=\"pdf-size\"\u003e(PDF - 4.7 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/6953\/46278a_2023-05-26.pdf\"\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pdf-list\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003e\u003ca rel=\"noopener\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/6661\/ob01900_matrix-1900.pdf\" target=\"_blank\"\u003eMatrix 1900 dimensions \u003cspan class=\"pdf-size\"\u003e(PDF - 0.5 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Osburn","offers":[{"title":"Default Title","offer_id":51361677345070,"sku":"OB01900","price":3499.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0731\/2159\/5694\/files\/ob01900_oa10041_web.jpg?v=1764722124"},{"product_id":"2000-i-wood-insert","title":"2000-I Wood Insert","description":"\u003ch3\u003e2000-I Wood Insert\u003c\/h3\u003e\n\u003cp\u003e\u003cem\u003eWood-burning inserts must only be installed inside an existing masonry fireplace and never in a wooden or combustible structure.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eThe new standard lowering the fine particulate emission threshold will be conquered by the recent certification of the Osburn 2000 wood burning stove. This revamped version now offers a particulate emissions rate of 2.3 g\/h, a maximum heat output of 75,000 BTU\/h and 79% optimum efficiency. This insert still has a 2.4 ft\u003csup\u003e3\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ecombustion chamber and a 144-CFM variable speed fan that is strategically positioned to redistribute heat throughout the room.\u003c\/p\u003e\n\u003cp\u003eDesigned to receive an optional faceplate that can cover a masonry hearth up to 32 inches (81 cm) high and 50 inches (127 cm) wide. A steel door overlay is available in black or brushed nickel as well as faceplate trims. Look no further, treat yourself to Osburn's legendary quality!\u003c\/p\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TyComb\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eHeating area :\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\"\u003e500 - 2,100 Ft\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output :\u003c\/td\u003e\n\u003ctd data-spec-id=\"PWMaSoi\"\u003e75,000 BTU\/h (22.0 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 class=\"h2\"\u003eAppliance performance\u003c\/h3\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TyComb\" colspan=\"2\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eRecommended heating area-ft² :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-inserts\/2000-wood-insert\/#recommended-maximum\" data-target-tab=\"fiche-technique\"\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\" colspan=\"2\"\u003e500 - 2,100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall firebox volume-ft³ :\u003c\/td\u003e\n\u003ctd data-spec-id=\"VolComi\" colspan=\"2\"\u003e2.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eEPA loading volume-ft³ :\u003c\/td\u003e\n\u003ctd data-spec-id=\"LoadEPA\" colspan=\"2\"\u003e1.95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum burn time :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-inserts\/2000-wood-insert\/#recommended-maximum\" data-target-tab=\"fiche-technique\"\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"TempComb\" colspan=\"2\"\u003e8 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output-dry cordwood :\u003c\/td\u003e\n\u003ctd data-spec-id=\"PWMaSoi\" colspan=\"2\"\u003e75,000 BTU\/h (22.0 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall heat output rate \u0026lt; :\u003c\/td\u003e\n\u003ctd data-spec-id=\"PwThMin,PwThMax\" colspan=\"2\"\u003e14,200 BTU\/h (4.16 kW) to 44,500 BTU\/h (13.04 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage overall efficiency (dry cordwood) :\u003c\/td\u003e\n\u003ctd data-spec-id=\"ReMoyGBmi\"\u003e72 % (HHV)\u003c\/td\u003e\n\u003ctd data-spec-id=\"RenMoyGBi\"\u003e77 % (LHV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum overall efficiency :\u003c\/td\u003e\n\u003ctd data-spec-id=\"EffOpti\" colspan=\"2\"\u003e79 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum heat transfer efficiency :\u003c\/td\u003e\n\u003ctd data-spec-id=\"RenOTCi\" colspan=\"2\"\u003e76 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage particulate emissions rate :\u003c\/td\u003e\n\u003ctd data-spec-id=\"Emiss\" colspan=\"2\"\u003e2.3 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage CO :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TauxCO\" colspan=\"2\"\u003e69 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp id=\"note-order-1\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e1\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eValues are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.\u003c\/p\u003e\n\u003cp id=\"recommended-maximum\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eRecommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.\u003c\/p\u003e\n\u003cp id=\"note-order-3\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e2\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThe maximum heat output (dry cordwood) is based on a loading density varying between 15 lb\/ft³ and 20 lb\/ft³ and reloading intervals ranging from 60 to 120 minutes. Other performances are based on a fuel load prescribed by the standard without any reloading between start and finish. The specified loading density varies between 7 lb\/ft³ and 12 lb\/ft³. The moisture content is between 19% and 25%.\u003c\/p\u003e\n\u003cp id=\"note-order-4\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e3\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eAs measured per CSA B415.1-10 stack loss method.\u003c\/p\u003e\n\u003cp id=\"note-order-5\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e4\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eHigher Heating Value of the fuel.\u003c\/p\u003e\n\u003cp id=\"note-order-6\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e5\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eLower Heating Value of the fuel.\u003c\/p\u003e\n\u003cp id=\"note-order-7\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e6\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ePerformances based on a fuel load prescribed by the standard at 7 lb\/ft³ and with a moisture content between 19% and 25%.\u003c\/p\u003e\n\u003cp id=\"note-order-8\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e7\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eOptimum overall efficiency at a specific burn rate (LHV).\u003c\/p\u003e\n\u003cp id=\"note-order-9\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e8\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThe optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.\u003c\/p\u003e\n\u003cp id=\"note-order-10\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e9\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThis appliance is officially tested and certified by an independent agency.\u003c\/p\u003e\n\u003cp id=\"note-order-11\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e10\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eCarbon monoxyde.\u003c\/p\u003e\n\u003ch3 class=\"h2\"\u003eGeneral features\u003c\/h3\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr data-spec-id=\"Techno\" data-order=\"0\"\u003e\n\u003ctd\u003eCombustion technology\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-catalytic\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"EPA\" data-order=\"26\"\u003e\n\u003ctd\u003eHigh-efficiency certified appliance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes, EPA 2020 approved\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"LongBuci\" data-order=\"33\"\u003e\n\u003ctd\u003eMaximum log length\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e20\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"PosBuch\" data-order=\"34\"\u003e\n\u003ctd\u003eLog positioning\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLoading over width\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DiaChei\" data-order=\"35\"\u003e\n\u003ctd\u003eChimney diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyChei\" data-order=\"38\"\u003e\n\u003ctd\u003eType of chimney\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLiner - ULC-S635, CAN\/ULC-S640, UL1777\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Hchei\" data-order=\"39\"\u003e\n\u003ctd\u003eMinimum chimney height (feet)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e12'\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Cfeu\" data-order=\"40\"\u003e\n\u003ctd\u003eBaffle type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC-Cast or equivalent\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"MaiMob\" data-order=\"42\"\u003e\n\u003ctd\u003eApproved for a mobile home installation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNo\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Poidi\" data-order=\"43\"\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e432 lb (196 kg)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyPorte\" data-order=\"44\"\u003e\n\u003ctd\u003eDoor type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSingle, glass with cast iron frame\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyVitre\" data-order=\"46\"\u003e\n\u003ctd\u003eGlass type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCeramic glass\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"SurfViti\" data-order=\"47\"\u003e\n\u003ctd\u003eGlass surface – dimensions (Width X Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e17 1\/8\" X 10 1\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"AutoCle\" data-order=\"48\"\u003e\n\u003ctd\u003eGlass air-wash system\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyVent\" data-order=\"50\"\u003e\n\u003ctd\u003ePremium quality blower included (CFM)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e144\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimExHHi\" data-order=\"56\"\u003e\n\u003ctd\u003eOverall dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e23 1\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimExHLi\" data-order=\"57\"\u003e\n\u003ctd\u003eOverall dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e28 3\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimExHPi\" data-order=\"58\"\u003e\n\u003ctd\u003eOverall dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e26 3\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimPorHi\" data-order=\"59\"\u003e\n\u003ctd\u003eDoor opening – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e9\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimPorLi\" data-order=\"60\"\u003e\n\u003ctd\u003eDoor opening - dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e17 1\/2\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimComHi\" data-order=\"61\"\u003e\n\u003ctd\u003eFirebox – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e11 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimComLi\" data-order=\"62\"\u003e\n\u003ctd\u003eFirebox – dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e21\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimComPi\" data-order=\"63\"\u003e\n\u003ctd\u003eFirebox – dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e16 3\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"BriRef\" data-order=\"64\"\u003e\n\u003ctd\u003eFirebox lined with refractory bricks for better heat distribution\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"SysAirSe\" data-order=\"66\"\u003e\n\u003ctd\u003eStainless-steel secondary-air system improving gas combustion\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Spadj\" data-order=\"67\"\u003e\n\u003ctd\u003eAdjustable threaded legs\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"EpAciCi\" data-order=\"69\"\u003e\n\u003ctd\u003eSteel thickness – body\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/16\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"EpAciDi\" data-order=\"70\"\u003e\n\u003ctd\u003eSteel thickness – top\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5\/16\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"OuvAHi\" data-order=\"83\"\u003e\n\u003ctd\u003eFireplace opening – minimum (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e23 3\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"OuvALi\" data-order=\"84\"\u003e\n\u003ctd\u003eFireplace opening – minimum (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e28 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"OuvAPi\" data-order=\"85\"\u003e\n\u003ctd\u003eFireplace opening – minimum (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e15 3\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoEmUs\" data-order=\"126\"\u003e\n\u003ctd\u003eUSA standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eComply with EPA 2020\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoEmCa\" data-order=\"127\"\u003e\n\u003ctd\u003eCanadian Standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCSA B415.1-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoSeUs\" data-order=\"128\"\u003e\n\u003ctd\u003eUSA standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUL 1482, UL 737\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoSeCa\" data-order=\"129\"\u003e\n\u003ctd\u003eCanadian standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eULC S628\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TestPar\" data-order=\"130\"\u003e\n\u003ctd\u003eTested and listed as per applicable standards\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBy an accredited laboratory (CAN\/USA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Garantie\" data-order=\"131\"\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLimited lifetime\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table-block site-margin no-margin-bottom\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cspan class=\"bold\"\u003eMinimum clearances to combustibles*\u003c\/span\u003e\u003cbr\u003e\u003cem\u003e(Data expressed in inches. 1 inch = 25.4 mm)\u003c\/em\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd colspan=\"1\" align=\"center\"\u003eCanada\u003c\/td\u003e\n\u003ctd colspan=\"1\" align=\"center\"\u003eUnited-States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – top (measured from the platform on which the appliance is installed)**\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – combustible side mantle to unit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e9\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e9\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – combustible top mantle to unit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e27\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e27\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – combustible side wall to unit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e16\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – minimum floor protection in front of the appliance\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e18''\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e16''\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance - from the top of the unit to the shelf\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e27\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – from the top of the insert to the shelf\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e27\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 class=\"h2 no-margin-top\"\u003eGuides\u003c\/h3\u003e\n\u003cp class=\"pdf-list\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003e\u003ca rel=\"noopener\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7111\/45927a_2024-02-28.pdf\" target=\"_blank\"\u003eOsburn 2000 wood insert install \u0026amp; owner's manual\u003cspan class=\"pdf-size\"\u003e(PDF - 6.0 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7111\/45927a_2024-02-28.pdf\"\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pdf-list\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003e\u003ca rel=\"noopener\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/4695\/ob02016_osburn-2000-i.pdf\" target=\"_blank\"\u003eOsburn 2000 dimensions\u003cspan class=\"pdf-size\"\u003e(PDF - 1.0 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/4695\/ob02016_osburn-2000-i.pdf\"\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 class=\"h2 no-margin-top\"\u003ePlans \u0026amp; CAD\u003c\/h3\u003e\n\u003cp class=\"pdf-list\"\u003e\u003cspan class=\"iconfont iconfont-stp\"\u003e\u003c\/span\u003e\u003ca rel=\"noopener\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5825\/ob02016.dwg\" target=\"_blank\"\u003e2D Diagrams\u003cspan class=\"pdf-size\"\u003e(DWG - 0.3 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pdf-list\"\u003e\u003cspan class=\"iconfont iconfont-stp\"\u003e\u003c\/span\u003e\u003ca rel=\"noopener\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5826\/ob02016.dxf\" target=\"_blank\"\u003e2D Diagrams\u003cspan class=\"pdf-size\"\u003e(DXF - 1.1 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Osburn","offers":[{"title":"Default Title","offer_id":51361683145006,"sku":"OB02016","price":3599.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0731\/2159\/5694\/files\/ob02016_2000_i_oa10237_ac03410_oa10122_web.jpg?v=1764722617"},{"product_id":"matrix-i-wood-insert","title":"MATRIX-I Wood Insert","description":"\u003ch3\u003eMATRIX-I Wood Insert\u003c\/h3\u003e\n\u003cp\u003e\u003cem\u003eWood-burning inserts must only be installed inside an existing masonry fireplace and never in a wooden or combustible structure.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eThe Matrix wood insert will seduce you with an average particle emission rate as 2.3 g\/h and an optimal efficiency of 79%. The latest modifications made to this box are well in tune with the industry standards required for 2020. Although it retains a unique style that is both massive and sleek, we have reviewed the door mechanism to make it more functional. Adding a set of intermediate trim panels may be required to complete your masonry hearth. Always the same legendary Osburn quality.\u003c\/p\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TyComb\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eHeating area :\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\"\u003e500 - 2,100 Ft\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output :\u003c\/td\u003e\n\u003ctd data-spec-id=\"PWMaSoi\"\u003e75,000 BTU\/h (22.0 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 class=\"h2\"\u003eAppliance performance\u003c\/h3\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"TyComb\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eRecommended heating area-ft² :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-inserts\/matrix-wood-insert\/#recommended-maximum\"\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"Surfi\"\u003e500 - 2,100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall firebox volume-ft³ :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"VolComi\"\u003e2.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eEPA loading volume-ft³ :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"LoadEPA\"\u003e1.95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum burn time :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca data-target-tab=\"fiche-technique\" href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-inserts\/matrix-wood-insert\/#recommended-maximum\"\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"TempComb\"\u003e8 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output-dry cordwood :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"PWMaSoi\"\u003e75,000 BTU\/h (22.0 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall heat output rate \u0026lt; :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"PwThMin,PwThMax\"\u003e14,200 BTU\/h (4.16 kW) to 44,500 BTU\/h (13.04 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage overall efficiency (dry cordwood) :\u003c\/td\u003e\n\u003ctd data-spec-id=\"ReMoyGBmi\"\u003e72 % (HHV)\u003c\/td\u003e\n\u003ctd data-spec-id=\"RenMoyGBi\"\u003e77 % (LHV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum overall efficiency :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"EffOpti\"\u003e79 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum heat transfer efficiency :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"RenOTCi\"\u003e76 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage particulate emissions rate :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"Emiss\"\u003e2.3 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage CO :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"TauxCO\"\u003e69 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"small\" id=\"note-order-1\"\u003e\u003csup\u003e(\u003cstrong\u003e1\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eValues are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"recommended-maximum\"\u003e\u003csup\u003e(\u003cstrong\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eRecommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-3\"\u003e\u003csup\u003e(\u003cstrong\u003e2\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThe maximum heat output (dry cordwood) is based on a loading density varying between 15 lb\/ft³ and 20 lb\/ft³ and reloading intervals ranging from 60 to 120 minutes. Other performances are based on a fuel load prescribed by the standard without any reloading between start and finish. The specified loading density varies between 7 lb\/ft³ and 12 lb\/ft³. The moisture content is between 19% and 25%.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-4\"\u003e\u003csup\u003e(\u003cstrong\u003e3\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eAs measured per CSA B415.1-10 stack loss method.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-5\"\u003e\u003csup\u003e(\u003cstrong\u003e4\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eHigher Heating Value of the fuel.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-6\"\u003e\u003csup\u003e(\u003cstrong\u003e5\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eLower Heating Value of the fuel.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-7\"\u003e\u003csup\u003e(\u003cstrong\u003e6\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ePerformances based on a fuel load prescribed by the standard at 7 lb\/ft³ and with a moisture content between 19% and 25%.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-8\"\u003e\u003csup\u003e(\u003cstrong\u003e7\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eOptimum overall efficiency at a specific burn rate (LHV).\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-9\"\u003e\u003csup\u003e(\u003cstrong\u003e8\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThe optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-10\"\u003e\u003csup\u003e(\u003cstrong\u003e9\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThis appliance is officially tested and certified by an independent agency.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-11\"\u003e\u003csup\u003e(\u003cstrong\u003e10\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eCarbon monoxyde.\u003c\/p\u003e\n\u003ch3 class=\"h2\"\u003eGeneral features\u003c\/h3\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr data-order=\"0\" data-spec-id=\"Techno\"\u003e\n\u003ctd\u003eCombustion technology\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-catalytic\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"26\" data-spec-id=\"EPA\"\u003e\n\u003ctd\u003eHigh-efficiency certified appliance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes, EPA 2020 approved\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"33\" data-spec-id=\"LongBuci\"\u003e\n\u003ctd\u003eMaximum log length\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e20\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"34\" data-spec-id=\"PosBuch\"\u003e\n\u003ctd\u003eLog positioning\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLoading over width\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"35\" data-spec-id=\"DiaChei\"\u003e\n\u003ctd\u003eChimney diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"36\" data-spec-id=\"DiaEvaci\"\u003e\n\u003ctd\u003eFlue outlet diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"38\" data-spec-id=\"TyChei\"\u003e\n\u003ctd\u003eType of chimney\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLiner - ULC-S635, CAN\/ULC-S640, UL1777\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"39\" data-spec-id=\"Hchei\"\u003e\n\u003ctd\u003eMinimum chimney height (feet)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e12'\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"40\" data-spec-id=\"Cfeu\"\u003e\n\u003ctd\u003eBaffle type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC-Cast or equivalent\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"42\" data-spec-id=\"MaiMob\"\u003e\n\u003ctd\u003eApproved for a mobile home installation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNo\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"43\" data-spec-id=\"Poidi\"\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e491 lb (223 kg)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"44\" data-spec-id=\"TyPorte\"\u003e\n\u003ctd\u003eDoor type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSingle, glass with cast iron frame\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"46\" data-spec-id=\"TyVitre\"\u003e\n\u003ctd\u003eGlass type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCeramic glass\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"47\" data-spec-id=\"SurfViti\"\u003e\n\u003ctd\u003eGlass surface – dimensions (Width X Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e19 5\/8\" X 11 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"48\" data-spec-id=\"AutoCle\"\u003e\n\u003ctd\u003eGlass air-wash system\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"50\" data-spec-id=\"TyVent\"\u003e\n\u003ctd\u003ePremium quality blower included (CFM)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e90\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"56\" data-spec-id=\"DimExHHi\"\u003e\n\u003ctd\u003eOverall dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e25 1\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"57\" data-spec-id=\"DimExHLi\"\u003e\n\u003ctd\u003eOverall dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e36 1\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"58\" data-spec-id=\"DimExHPi\"\u003e\n\u003ctd\u003eOverall dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e23 1\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"59\" data-spec-id=\"DimPorHi\"\u003e\n\u003ctd\u003eDoor opening – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e8 3\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"60\" data-spec-id=\"DimPorLi\"\u003e\n\u003ctd\u003eDoor opening - dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e17 1\/2\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"61\" data-spec-id=\"DimComHi\"\u003e\n\u003ctd\u003eFirebox – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e11 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"62\" data-spec-id=\"DimComLi\"\u003e\n\u003ctd\u003eFirebox – dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e21\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"63\" data-spec-id=\"DimComPi\"\u003e\n\u003ctd\u003eFirebox – dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e16 3\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"64\" data-spec-id=\"BriRef\"\u003e\n\u003ctd\u003eFirebox lined with refractory bricks for better heat distribution\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"66\" data-spec-id=\"SysAirSe\"\u003e\n\u003ctd\u003eStainless-steel secondary-air system improving gas combustion\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"69\" data-spec-id=\"EpAciCi\"\u003e\n\u003ctd\u003eSteel thickness – body\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/16\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"70\" data-spec-id=\"EpAciDi\"\u003e\n\u003ctd\u003eSteel thickness – top\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5\/16\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"83\" data-spec-id=\"OuvAHi\"\u003e\n\u003ctd\u003eFireplace opening – minimum (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e23 3\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"84\" data-spec-id=\"OuvALi\"\u003e\n\u003ctd\u003eFireplace opening – minimum (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e28 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"85\" data-spec-id=\"OuvAPi\"\u003e\n\u003ctd\u003eFireplace opening – minimum (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e19 5\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"126\" data-spec-id=\"NoEmUs\"\u003e\n\u003ctd\u003eUSA standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEPA \/ ASTM WK47329\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"127\" data-spec-id=\"NoEmCa\"\u003e\n\u003ctd\u003eCanadian Standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCSA B415.1-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"128\" data-spec-id=\"NoSeUs\"\u003e\n\u003ctd\u003eUSA standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUL 1482, UL 737\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"129\" data-spec-id=\"NoSeCa\"\u003e\n\u003ctd\u003eCanadian standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eULC S628\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"130\" data-spec-id=\"TestPar\"\u003e\n\u003ctd\u003eTested and listed as per applicable standards\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBy an accredited laboratory (CAN\/USA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"131\" data-spec-id=\"Garantie\"\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLimited lifetime\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table-block site-margin no-margin-bottom\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cspan class=\"bold\"\u003eMinimum clearances to combustibles*\u003c\/span\u003e\u003cbr\u003e\u003cem\u003e(Data expressed in inches. 1 inch = 25.4 mm)\u003c\/em\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd align=\"center\" colspan=\"1\"\u003eCanada\u003c\/td\u003e\n\u003ctd align=\"center\" colspan=\"1\"\u003eUnited-States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – combustible side mantle to unit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e9\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e9\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – combustible top mantle to unit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e27\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e27\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – combustible side wall to unit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e16\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – minimum floor protection in front of the appliance\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e18\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance - from the top of the unit to the shelf\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e27\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – from the top of the insert to the shelf\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e27\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 class=\"h2 no-margin-top\"\u003eGuides\u003c\/h3\u003e\n\u003cp class=\"pdf-list\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003e\u003ca rel=\"noopener\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7115\/45929a_2024-02-29.pdf\" target=\"_blank\"\u003eOsburn Matrix wood insert install \u0026amp; owner's manual\u003cspan class=\"pdf-size\"\u003e(PDF - 6.3 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7115\/45929a_2024-02-29.pdf\"\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pdf-list\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003e\u003ca rel=\"noopener\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/4680\/ob02028_osburn-matrix-i.pdf\" target=\"_blank\"\u003eOsburn Matrix dimensions\u003cspan class=\"pdf-size\"\u003e(PDF - 0.4 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pdf-list\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003e\u003ca rel=\"noopener\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7052\/46372af_2023-11-24.pdf\" target=\"_blank\"\u003eMatrix door handle replacement instructions\u003cspan class=\"pdf-size\"\u003e(PDF - 2.8 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Osburn","offers":[{"title":"Default Title","offer_id":51361685143854,"sku":"OB02028","price":4099.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0731\/2159\/5694\/files\/ob02028_matrix_web.jpg?v=1764722862"},{"product_id":"inspire-2000-i-wood-insert","title":"INSPIRE 2000-I Wood Insert","description":"\u003ch3\u003eINSPIRE 2000-I Wood Insert\u003c\/h3\u003e\n\u003cp\u003e\u003cem\u003eWood-burning inserts must only be installed inside an existing masonry fireplace and never in a wooden or combustible structure.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eThis wood insert will bring an unmatched modernism to your decor, in addition to perfectly combining functionality and comfort. The impeccable lines display a timeless style while guaranteeing reliability and durability.\u003c\/p\u003e\n\u003cp\u003eWhether you want to enjoy a broad view of the flames in the comfort of your living room during a romantic evening or simply to benefit from impressive heat in cold weather, the Inspire will charm you as much by its aesthetics as its 79% optimal performance . With its particle emission rate as 2.3 g\/h and its high-performance combustion system, environmentalists have never been as happy with wood heating. The Inspire Collection celebrates our past and embraces our future as our team is committed \u003cspan\u003emore than ever\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eto our industry's contribution to sustainability . A dream opportunity on the latest trends!\u003c\/p\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TyComb\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eHeating area :\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\"\u003e500 - 2,100 Ft\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output :\u003c\/td\u003e\n\u003ctd data-spec-id=\"PWMaSoi\"\u003e75,000 BTU\/h (22 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 class=\"h2\"\u003eAppliance performance\u003c\/h3\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TyComb\" colspan=\"2\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eRecommended heating area-ft² :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-inserts\/inspire-wood-insert\/#recommended-maximum\" data-target-tab=\"fiche-technique\"\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\" colspan=\"2\"\u003e500 - 2,100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall firebox volume-ft³ :\u003c\/td\u003e\n\u003ctd data-spec-id=\"VolComi\" colspan=\"2\"\u003e2.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eEPA loading volume-ft³ :\u003c\/td\u003e\n\u003ctd data-spec-id=\"LoadEPA\" colspan=\"2\"\u003e1.95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum burn time :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-inserts\/inspire-wood-insert\/#recommended-maximum\" data-target-tab=\"fiche-technique\"\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"TempComb\" colspan=\"2\"\u003e8 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output-dry cordwood :\u003c\/td\u003e\n\u003ctd data-spec-id=\"PWMaSoi\" colspan=\"2\"\u003e75,000 BTU\/h (22 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall heat output rate \u0026lt; :\u003c\/td\u003e\n\u003ctd data-spec-id=\"PwThMin,PwThMax\" colspan=\"2\"\u003e14,200 BTU\/h (4.16 kW) to 44,500 BTU\/h (13.04 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage overall efficiency (dry cordwood) :\u003c\/td\u003e\n\u003ctd data-spec-id=\"ReMoyGBmi\"\u003e72 % (HHV)\u003c\/td\u003e\n\u003ctd data-spec-id=\"RenMoyGBi\"\u003e77 % (LHV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum overall efficiency :\u003c\/td\u003e\n\u003ctd data-spec-id=\"EffOpti\" colspan=\"2\"\u003e79 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum heat transfer efficiency :\u003c\/td\u003e\n\u003ctd data-spec-id=\"RenOTCi\" colspan=\"2\"\u003e76 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage particulate emissions rate :\u003c\/td\u003e\n\u003ctd data-spec-id=\"Emiss\" colspan=\"2\"\u003e2.3 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003e\n\u003cp\u003eAverage CO :\u003csup\u003e\u003c\/sup\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"TauxCO\" colspan=\"2\"\u003e69 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp id=\"note-order-1\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e1\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eValues are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.\u003c\/p\u003e\n\u003cp id=\"recommended-maximum\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eRecommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.\u003c\/p\u003e\n\u003cp id=\"note-order-3\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e2\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThe maximum heat output (dry cordwood) is based on a loading density varying between 15 lb\/ft³ and 20 lb\/ft³ and reloading intervals ranging from 60 to 120 minutes. Other performances are based on a fuel load prescribed by the standard without any reloading between start and finish. The specified loading density varies between 7 lb\/ft³ and 12 lb\/ft³. The moisture content is between 19% and 25%.\u003c\/p\u003e\n\u003cp id=\"note-order-4\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e3\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eAs measured per CSA B415.1-10 stack loss method.\u003c\/p\u003e\n\u003cp id=\"note-order-5\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e4\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eHigher Heating Value of the fuel.\u003c\/p\u003e\n\u003cp id=\"note-order-6\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e5\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eLower Heating Value of the fuel.\u003c\/p\u003e\n\u003cp id=\"note-order-7\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e6\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ePerformances based on a fuel load prescribed by the standard at 7 lb\/ft³ and with a moisture content between 19% and 25%.\u003c\/p\u003e\n\u003cp id=\"note-order-8\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e7\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eOptimum overall efficiency at a specific burn rate (LHV).\u003c\/p\u003e\n\u003cp id=\"note-order-9\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e8\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThe optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.\u003c\/p\u003e\n\u003cp id=\"note-order-10\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e9\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThis appliance is officially tested and certified by an independent agency.\u003c\/p\u003e\n\u003cp id=\"note-order-11\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e10\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eCarbon monoxyde.\u003c\/p\u003e\n\u003ch3 class=\"h2\"\u003eGeneral features\u003c\/h3\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr data-spec-id=\"Techno\" data-order=\"0\"\u003e\n\u003ctd\u003eCombustion technology\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-catalytic\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"EPA\" data-order=\"26\"\u003e\n\u003ctd\u003eHigh-efficiency certified appliance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes, EPA 2020 approved\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"LongBuci\" data-order=\"33\"\u003e\n\u003ctd\u003eMaximum log length\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e20\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"PosBuch\" data-order=\"34\"\u003e\n\u003ctd\u003eLog positioning\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLoading over width\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DiaChei\" data-order=\"35\"\u003e\n\u003ctd\u003eChimney diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DiaEvaci\" data-order=\"36\"\u003e\n\u003ctd\u003eFlue outlet diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyChei\" data-order=\"38\"\u003e\n\u003ctd\u003eType of chimney\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLiner - ULC-S635, CAN\/ULC-S640, UL1777\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Hchei\" data-order=\"39\"\u003e\n\u003ctd\u003eMinimum chimney height (feet)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e12'\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Cfeu\" data-order=\"40\"\u003e\n\u003ctd\u003eBaffle type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC-Cast or equivalent\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"MaiMob\" data-order=\"42\"\u003e\n\u003ctd\u003eApproved for a mobile home installation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNo\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Poidi\" data-order=\"43\"\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e435 lb (197 kg)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyPorte\" data-order=\"44\"\u003e\n\u003ctd\u003eDoor type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSingle, glass with steel frame\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyVitre\" data-order=\"46\"\u003e\n\u003ctd\u003eGlass type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCeramic glass\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"SurfViti\" data-order=\"47\"\u003e\n\u003ctd\u003eGlass surface – dimensions (Width X Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e20 1\/4\" X 9 1\/2\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"AutoCle\" data-order=\"48\"\u003e\n\u003ctd\u003eGlass air-wash system\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyVent\" data-order=\"50\"\u003e\n\u003ctd\u003ePremium quality blower included (CFM)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e176\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimExHHi\" data-order=\"56\"\u003e\n\u003ctd\u003eOverall dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e24 3\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimExHLi\" data-order=\"57\"\u003e\n\u003ctd\u003eOverall dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e28 1\/2\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimExHPi\" data-order=\"58\"\u003e\n\u003ctd\u003eOverall dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e20 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimPorHi\" data-order=\"59\"\u003e\n\u003ctd\u003eDoor opening – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e8 1\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimPorLi\" data-order=\"60\"\u003e\n\u003ctd\u003eDoor opening - dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e20\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimComHi\" data-order=\"61\"\u003e\n\u003ctd\u003eFirebox – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e11 3\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimComLi\" data-order=\"62\"\u003e\n\u003ctd\u003eFirebox – dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e21\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimComPi\" data-order=\"63\"\u003e\n\u003ctd\u003eFirebox – dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e16 3\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"BriRef\" data-order=\"64\"\u003e\n\u003ctd\u003eFirebox lined with refractory bricks for better heat distribution\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"SysAirSe\" data-order=\"66\"\u003e\n\u003ctd\u003eStainless-steel secondary-air system improving gas combustion\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"EpAciCi\" data-order=\"69\"\u003e\n\u003ctd\u003eSteel thickness – body\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/16\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"EpAciDi\" data-order=\"70\"\u003e\n\u003ctd\u003eSteel thickness – top\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"OuvAHi\" data-order=\"83\"\u003e\n\u003ctd\u003eFireplace opening – minimum (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e24 5\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"OuvALi\" data-order=\"84\"\u003e\n\u003ctd\u003eFireplace opening – minimum (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e29\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"OuvAPi\" data-order=\"85\"\u003e\n\u003ctd\u003eFireplace opening – minimum (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e20 3\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoEmUs\" data-order=\"126\"\u003e\n\u003ctd\u003eUSA standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEPA Method 28\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoEmCa\" data-order=\"127\"\u003e\n\u003ctd\u003eCanadian Standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCSA B415.1-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoSeUs\" data-order=\"128\"\u003e\n\u003ctd\u003eUSA standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUL 1482, UL 737\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoSeCa\" data-order=\"129\"\u003e\n\u003ctd\u003eCanadian standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eULC S628\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TestPar\" data-order=\"130\"\u003e\n\u003ctd\u003eTested and listed as per applicable standards\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBy an accredited laboratory (CAN\/USA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Garantie\" data-order=\"131\"\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLimited lifetime\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table-block site-margin no-margin-bottom\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cspan class=\"bold\"\u003eMinimum clearances to combustibles*\u003c\/span\u003e\u003cbr\u003e\u003cem\u003e(Data expressed in inches. 1 inch = 25.4 mm)\u003c\/em\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd colspan=\"1\" align=\"center\"\u003eCanada\u003c\/td\u003e\n\u003ctd colspan=\"1\" align=\"center\"\u003eUnited-States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – top (measured from the platform on which the appliance is installed)**\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – combustible side mantle to unit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e9\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e9\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – combustible top mantle to unit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e27\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e27\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – combustible side wall to unit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e16\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – minimum floor protection in front of the appliance\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e18\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance - from the top of the unit to the shelf\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e27\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – from the top of the insert to the shelf\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e27\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 class=\"h2 no-margin-top\"\u003eGuides\u003c\/h4\u003e\n\u003cp class=\"pdf-list\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7721\/45952a_2025-07-10.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOsburn Inspire wood insert install \u0026amp; owner's manual\u003cspan class=\"pdf-size\"\u003e(PDF - 7.2 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pdf-list\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/4659\/ob02045_osburn-inspire-2000-i-nord-am%C3%A9ricain.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOsburn Inspire dimensions\u003cspan class=\"pdf-size\"\u003e(PDF)\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/4659\/ob02045_osburn-inspire-2000-i-nord-am%C3%A9ricain.pdf\" class=\"pdf-list-link\"\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pdf-list\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/4710\/45939a_14-11-2018.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFaceplates Installation Instructions\u003cspan class=\"pdf-size\"\u003e(PDF - 0.9 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/4710\/45939a_14-11-2018.pdf\" class=\"pdf-list-link\"\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4 class=\"h2 no-margin-top\"\u003ePlans \u0026amp; CAD\u003c\/h4\u003e\n\u003cp class=\"pdf-list\"\u003e\u003cspan class=\"iconfont iconfont-stp\"\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5829\/ob02045.dwg\" target=\"_blank\" rel=\"noopener\"\u003e2D Diagrams\u003cspan class=\"pdf-size\"\u003e(DWG - 0.4 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5829\/ob02045.dwg\" class=\"pdf-list-link\"\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pdf-list\"\u003e\u003cspan class=\"iconfont iconfont-stp\"\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5830\/ob02045.dxf\" target=\"_blank\" rel=\"noopener\"\u003e2D Diagrams\u003cspan class=\"pdf-size\"\u003e(DXF - 1.2 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Osburn","offers":[{"title":"Default Title","offer_id":51361687503150,"sku":"OB02045","price":4049.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0731\/2159\/5694\/files\/ob02045_ac01021_v2_web.jpg?v=1764723137"},{"product_id":"3500-i-wood-insert","title":"3500-I Wood Insert","description":"\u003ch3\u003e3500-I Wood Insert\u003c\/h3\u003e\n\u003cp\u003e\u003cem\u003eWood-burning inserts must only be installed inside an existing masonry fireplace and never in a wooden or combustible structure.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eThe Osburn 3500 wood insert combines power, efficiency and safety. With its amazing features and sober lines that give way to one of the largest glass surfaces in its category, this insert will blend perfectly with the architecture of your home. Its flawless design reveals all the Canadian know-how in terms of alternative heating and will quickly become the house favorite. No harsh winter can resist it! \u003c\/p\u003e\n\u003cp\u003eBecause each house is unique, choose the door overlay, the faceplate and the trims that suit you!\u003c\/p\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TyComb\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eHeating area :\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\"\u003e1,000 - 2,700 Ft\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output :\u003c\/td\u003e\n\u003ctd data-spec-id=\"PWMaSoi\"\u003e110,000 BTU\/h (32.2 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 class=\"h2\"\u003eAppliance performance\u003c\/h3\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"TyComb\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eRecommended heating area-ft² :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"Surfi\"\u003e1,000 - 2,700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall firebox volume-ft³ :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"VolComi\"\u003e3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eEPA loading volume-ft³ :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"LoadEPA\"\u003e2.88\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum burn time :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"TempComb\"\u003e10 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output-dry cordwood :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"PWMaSoi\"\u003e110,000 BTU\/h (32.2 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall heat output rate \u0026lt; :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"PwThMin,PwThMax\"\u003e17,200 BTU\/h (5.0 kW) to 57,800 BTU\/h (16.9 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage overall efficiency (dry cordwood) :\u003c\/td\u003e\n\u003ctd data-spec-id=\"ReMoyGBmi\"\u003e71 % (HHV)\u003c\/td\u003e\n\u003ctd data-spec-id=\"RenMoyGBi\"\u003e76 % (LHV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum overall efficiency :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"EffOpti\"\u003e77 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum heat transfer efficiency :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"RenOTCi\"\u003e75 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage particulate emissions rate :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"Emiss\"\u003e1.6 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage CO :\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-spec-id=\"TauxCO\"\u003e73 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"small\" id=\"note-order-1\"\u003e\u003csup\u003e(\u003cstrong\u003e1\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eValues are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"recommended-maximum\"\u003e\u003csup\u003e(\u003cstrong\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eRecommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-3\"\u003e\u003csup\u003e(\u003cstrong\u003e2\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThe maximum heat output (dry cordwood) is based on a loading density varying between 15 lb\/ft³ and 20 lb\/ft³ and reloading intervals ranging from 60 to 120 minutes. Other performances are based on a fuel load prescribed by the standard without any reloading between start and finish. The specified loading density varies between 7 lb\/ft³ and 12 lb\/ft³. The moisture content is between 19% and 25%.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-4\"\u003e\u003csup\u003e(\u003cstrong\u003e3\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eAs measured per CSA B415.1-10 stack loss method.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-5\"\u003e\u003csup\u003e(\u003cstrong\u003e4\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eHigher Heating Value of the fuel.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-6\"\u003e\u003csup\u003e(\u003cstrong\u003e5\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eLower Heating Value of the fuel.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-7\"\u003e\u003csup\u003e(\u003cstrong\u003e6\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ePerformances based on a fuel load prescribed by the standard at 7 lb\/ft³ and with a moisture content between 19% and 25%.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-8\"\u003e\u003csup\u003e(\u003cstrong\u003e7\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eOptimum overall efficiency at a specific burn rate (LHV).\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-9\"\u003e\u003csup\u003e(\u003cstrong\u003e8\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThe optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-10\"\u003e\u003csup\u003e(\u003cstrong\u003e9\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThis appliance is officially tested and certified by an independent agency.\u003c\/p\u003e\n\u003cp class=\"small\" id=\"note-order-11\"\u003e\u003csup\u003e(\u003cstrong\u003e10\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eCarbon monoxyde.\u003c\/p\u003e\n\u003ch3 class=\"h2\"\u003eGeneral features\u003c\/h3\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr data-order=\"0\" data-spec-id=\"Techno\"\u003e\n\u003ctd\u003eCombustion technology\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-catalytic\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"26\" data-spec-id=\"EPA\"\u003e\n\u003ctd\u003eHigh-efficiency certified appliance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes, EPA 2020 approved\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"33\" data-spec-id=\"LongBuci\"\u003e\n\u003ctd\u003eMaximum log length\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e22\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"34\" data-spec-id=\"PosBuch\"\u003e\n\u003ctd\u003eLog positioning\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLoading over width and over depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"35\" data-spec-id=\"DiaChei\"\u003e\n\u003ctd\u003eChimney diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"36\" data-spec-id=\"DiaEvaci\"\u003e\n\u003ctd\u003eFlue outlet diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"38\" data-spec-id=\"TyChei\"\u003e\n\u003ctd\u003eType of chimney\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLiner - ULC-S635, CAN\/ULC-S640, UL1777\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"39\" data-spec-id=\"Hchei\"\u003e\n\u003ctd\u003eMinimum chimney height (feet)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e15'\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"40\" data-spec-id=\"Cfeu\"\u003e\n\u003ctd\u003eBaffle type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC-Cast or equivalent\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"42\" data-spec-id=\"MaiMob\"\u003e\n\u003ctd\u003eApproved for a mobile home installation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNo\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"43\" data-spec-id=\"Poidi\"\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e540 lb (245 kg)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"44\" data-spec-id=\"TyPorte\"\u003e\n\u003ctd\u003eDoor type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSingle, glass with cast iron frame\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"46\" data-spec-id=\"TyVitre\"\u003e\n\u003ctd\u003eGlass type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCeramic glass\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"47\" data-spec-id=\"SurfViti\"\u003e\n\u003ctd\u003eGlass surface – dimensions (Width X Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e18 7\/8\" X 11 3\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"48\" data-spec-id=\"AutoCle\"\u003e\n\u003ctd\u003eGlass air-wash system\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"50\" data-spec-id=\"TyVent\"\u003e\n\u003ctd\u003ePremium quality blower included (CFM)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e144\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"56\" data-spec-id=\"DimExHHi\"\u003e\n\u003ctd\u003eOverall dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e24 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"57\" data-spec-id=\"DimExHLi\"\u003e\n\u003ctd\u003eOverall dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e30 3\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"58\" data-spec-id=\"DimExHPi\"\u003e\n\u003ctd\u003eOverall dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e29\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"59\" data-spec-id=\"DimPorHi\"\u003e\n\u003ctd\u003eDoor opening – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e9 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"60\" data-spec-id=\"DimPorLi\"\u003e\n\u003ctd\u003eDoor opening - dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e19\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"61\" data-spec-id=\"DimComHi\"\u003e\n\u003ctd\u003eFirebox – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e12 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"62\" data-spec-id=\"DimComLi\"\u003e\n\u003ctd\u003eFirebox – dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e22 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"63\" data-spec-id=\"DimComPi\"\u003e\n\u003ctd\u003eFirebox – dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e20 1\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"64\" data-spec-id=\"BriRef\"\u003e\n\u003ctd\u003eFirebox lined with refractory bricks for better heat distribution\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"66\" data-spec-id=\"SysAirSe\"\u003e\n\u003ctd\u003eStainless-steel secondary-air system improving gas combustion\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"69\" data-spec-id=\"EpAciCi\"\u003e\n\u003ctd\u003eSteel thickness – body\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/16\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"70\" data-spec-id=\"EpAciDi\"\u003e\n\u003ctd\u003eSteel thickness – top\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5\/16\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"83\" data-spec-id=\"OuvAHi\"\u003e\n\u003ctd\u003eFireplace opening – minimum (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e26 1\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"84\" data-spec-id=\"OuvALi\"\u003e\n\u003ctd\u003eFireplace opening – minimum (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e31\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"85\" data-spec-id=\"OuvAPi\"\u003e\n\u003ctd\u003eFireplace opening – minimum (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e18 3\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"126\" data-spec-id=\"NoEmUs\"\u003e\n\u003ctd\u003eUSA standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEPA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"127\" data-spec-id=\"NoEmCa\"\u003e\n\u003ctd\u003eCanadian Standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCSA B415.1-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"128\" data-spec-id=\"NoSeUs\"\u003e\n\u003ctd\u003eUSA standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUL 1482, UL 737\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"129\" data-spec-id=\"NoSeCa\"\u003e\n\u003ctd\u003eCanadian standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eULC S628\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"130\" data-spec-id=\"TestPar\"\u003e\n\u003ctd\u003eTested and listed as per applicable standards\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBy an accredited laboratory (CAN\/USA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-order=\"131\" data-spec-id=\"Garantie\"\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLimited lifetime\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table-block site-margin no-margin-bottom\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cspan class=\"bold\"\u003eMinimum clearances to combustibles*\u003c\/span\u003e\u003cbr\u003e\u003cem\u003e(Data expressed in inches. 1 inch = 25.4 mm)\u003c\/em\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd align=\"center\" colspan=\"1\"\u003eCanada\u003c\/td\u003e\n\u003ctd align=\"center\" colspan=\"1\"\u003eUnited-States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – top (measured from the platform on which the appliance is installed)**\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – combustible side mantle to unit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e9\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e9\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – combustible top mantle to unit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e27\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e27\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – combustible side wall to unit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e19\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e19\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance - from the top of the unit to the shelf\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e27\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – from the top of the insert to the shelf\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e27\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 class=\"h2 no-margin-top\"\u003eGuides\u003c\/h4\u003e\n\u003cp class=\"pdf-list\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003e\u003ca rel=\"noopener\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7017\/46180a_2023-08-25.pdf\" target=\"_blank\"\u003eOsburn 3500-I wood insert install \u0026amp; owner's manual\u003cspan class=\"pdf-size\"\u003e(PDF - 8.8 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pdf-list\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003e\u003ca rel=\"noopener\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5672\/ob03510-osburn-35-i.pdf\" target=\"_blank\"\u003eOsburn 3500-I dimensions\u003cspan class=\"pdf-size\"\u003e(PDF - 0.6 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5672\/ob03510-osburn-35-i.pdf\"\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4 class=\"h2 no-margin-top\"\u003ePlans \u0026amp; CAD\u003c\/h4\u003e\n\u003cp class=\"pdf-list\"\u003e\u003cspan class=\"iconfont iconfont-stp\"\u003e\u003c\/span\u003e\u003ca rel=\"noopener\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5968\/ob03510.dwg\" target=\"_blank\"\u003e2D Diagrams\u003cspan class=\"pdf-size\"\u003e(DWG - 0.3 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pdf-list\"\u003e\u003cspan class=\"iconfont iconfont-stp\"\u003e\u003c\/span\u003e\u003ca rel=\"noopener\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5969\/ob03510.dxf\" target=\"_blank\"\u003e2D Diagrams\u003cspan class=\"pdf-size\"\u003e(DXF - 1.7 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Osburn","offers":[{"title":"Default Title","offer_id":51361689633070,"sku":"OB03510","price":4399.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0731\/2159\/5694\/files\/ob03510_oa10163_oa10032_oa10125_web.jpg?v=1764723353"},{"product_id":"matrix-2700-wood-insert","title":"MATRIX 2700 Wood Insert","description":"\u003ch3\u003eMATRIX 2700 Wood Insert\u003c\/h3\u003e\n\u003cp\u003e\u003cem\u003eWood-burning inserts must only be installed inside an existing masonry fireplace and never in a wooden or combustible structure.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eInspired by nature, the Matrix 2700 insert is a fusion of traditional style and technological innovation. Located in the heart of your living space, the generous viewing area of the Matrix 2700 will invite you to sit back, relax and take in the calm and warmth of its flames. Eco-savvy consumers will appreciate its efficient combustion, quality performance and classic beauty.\u003c\/p\u003e\n\u003cp\u003eThis unit comes standard with cast iron faceplate and heat activated blower. Customize the look of this non-catalytic appliance by choosing from a black or brushed silver-plated door overlay and fire screen.\u003c\/p\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TyComb\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eHeating area :\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\"\u003e750 - 2,200 Ft\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output :\u003c\/td\u003e\n\u003ctd data-spec-id=\"PWMaSoi\"\u003e80,000 BTU\/h (23.4 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 class=\"h2\"\u003eAppliance performance\u003c\/h3\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TyComb\" colspan=\"2\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eRecommended heating area-ft² :\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\" colspan=\"2\"\u003e750 - 2,200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall firebox volume-ft³ :\u003c\/td\u003e\n\u003ctd data-spec-id=\"VolComi\" colspan=\"2\"\u003e2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eEPA loading volume-ft³ :\u003c\/td\u003e\n\u003ctd data-spec-id=\"LoadEPA\" colspan=\"2\"\u003e1.94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum burn time :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TempComb\" colspan=\"2\"\u003e8 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output-dry cordwood :\u003c\/td\u003e\n\u003ctd data-spec-id=\"PWMaSoi\" colspan=\"2\"\u003e80,000 BTU\/h (23.4 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall heat output rate \u0026lt; :\u003c\/td\u003e\n\u003ctd data-spec-id=\"PwThMin,PwThMax\" colspan=\"2\"\u003e12,700 BTU\/h (3.72 kW) to 60,700 BTU\/h (17.79 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage overall efficiency (dry cordwood) :\u003c\/td\u003e\n\u003ctd data-spec-id=\"ReMoyGBmi\"\u003e64 % (HHV)\u003c\/td\u003e\n\u003ctd data-spec-id=\"RenMoyGBi\"\u003e68 % (LHV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum overall efficiency :\u003c\/td\u003e\n\u003ctd data-spec-id=\"EffOpti\" colspan=\"2\"\u003e70 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum heat transfer efficiency :\u003c\/td\u003e\n\u003ctd data-spec-id=\"RenOTCi\" colspan=\"2\"\u003e68 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage particulate emissions rate :\u003c\/td\u003e\n\u003ctd data-spec-id=\"Emiss\" colspan=\"2\"\u003e1.2 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage CO :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TauxCO\" colspan=\"2\"\u003e98 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp id=\"note-order-1\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e1\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eValues are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.\u003c\/p\u003e\n\u003cp id=\"recommended-maximum\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eRecommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.\u003c\/p\u003e\n\u003cp id=\"note-order-3\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e2\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThe maximum heat output (dry cordwood) is based on a loading density varying between 15 lb\/ft³ and 20 lb\/ft³ and reloading intervals ranging from 60 to 120 minutes. Other performances are based on a fuel load prescribed by the standard without any reloading between start and finish. The specified loading density varies between 7 lb\/ft³ and 12 lb\/ft³. The moisture content is between 19% and 25%.\u003c\/p\u003e\n\u003cp id=\"note-order-4\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e3\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eAs measured per CSA B415.1-10 stack loss method.\u003c\/p\u003e\n\u003cp id=\"note-order-5\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e4\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eHigher Heating Value of the fuel.\u003c\/p\u003e\n\u003cp id=\"note-order-6\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e5\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eLower Heating Value of the fuel.\u003c\/p\u003e\n\u003cp id=\"note-order-7\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e6\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ePerformances based on a fuel load prescribed by the standard at 7 lb\/ft³ and with a moisture content between 19% and 25%.\u003c\/p\u003e\n\u003cp id=\"note-order-8\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e7\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eOptimum overall efficiency at a specific burn rate (LHV).\u003c\/p\u003e\n\u003cp id=\"note-order-9\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e8\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThe optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.\u003c\/p\u003e\n\u003cp id=\"note-order-10\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e9\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThis appliance is officially tested and certified by an independent agency.\u003c\/p\u003e\n\u003cp id=\"note-order-11\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e10\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eCarbon monoxyde.\u003c\/p\u003e\n\u003ch3 class=\"h2\"\u003eGeneral features\u003c\/h3\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr data-spec-id=\"Techno\" data-order=\"0\"\u003e\n\u003ctd\u003eCombustion technology\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-catalytic\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"EPA\" data-order=\"26\"\u003e\n\u003ctd\u003eHigh-efficiency certified appliance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes, EPA 2020 approved\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"LongBuci\" data-order=\"33\"\u003e\n\u003ctd\u003eMaximum log length\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e20\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"PosBuch\" data-order=\"34\"\u003e\n\u003ctd\u003eLog positioning\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLoading over width\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DiaChei\" data-order=\"35\"\u003e\n\u003ctd\u003eChimney diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DiaEvaci\" data-order=\"36\"\u003e\n\u003ctd\u003eFlue outlet diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyChei\" data-order=\"38\"\u003e\n\u003ctd\u003eType of chimney\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLiner - ULC-S635, CAN\/ULC-S640, UL1777\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Hchei\" data-order=\"39\"\u003e\n\u003ctd\u003eMinimum chimney height (feet)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e15'\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Cfeu\" data-order=\"40\"\u003e\n\u003ctd\u003eBaffle type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC-Cast or equivalent\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"MaiMob\" data-order=\"42\"\u003e\n\u003ctd\u003eApproved for a mobile home installation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNo\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Poidi\" data-order=\"43\"\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e535 lb (243kg)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyPorte\" data-order=\"44\"\u003e\n\u003ctd\u003eDoor type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSingle, glass with cast iron frame\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyVitre\" data-order=\"46\"\u003e\n\u003ctd\u003eGlass type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCeramic glass\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"SurfViti\" data-order=\"47\"\u003e\n\u003ctd\u003eGlass surface – dimensions (Width X Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e24 3\/8\" X 12 5\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"AutoCle\" data-order=\"48\"\u003e\n\u003ctd\u003eGlass air-wash system\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TyVent\" data-order=\"50\"\u003e\n\u003ctd\u003ePremium quality blower included (CFM)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e176\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimExHHi\" data-order=\"56\"\u003e\n\u003ctd\u003eOverall dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e30 1\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimExHLi\" data-order=\"57\"\u003e\n\u003ctd\u003eOverall dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e43 5\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimExHPi\" data-order=\"58\"\u003e\n\u003ctd\u003eOverall dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e27 1\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimPorHi\" data-order=\"59\"\u003e\n\u003ctd\u003eDoor opening – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 1\/2\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimPorLi\" data-order=\"60\"\u003e\n\u003ctd\u003eDoor opening - dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e25 3\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimComHi\" data-order=\"61\"\u003e\n\u003ctd\u003eFirebox – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e12 3\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimComLi\" data-order=\"62\"\u003e\n\u003ctd\u003eFirebox – dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e22 5\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"DimComPi\" data-order=\"63\"\u003e\n\u003ctd\u003eFirebox – dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e12 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"PRefrM\" data-order=\"65\"\u003e\n\u003ctd\u003eMoulded refractory bricks\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"SysAirSe\" data-order=\"66\"\u003e\n\u003ctd\u003eStainless-steel secondary-air system improving gas combustion\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Spadj\" data-order=\"67\"\u003e\n\u003ctd\u003eAdjustable threaded legs\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"EpAciCi\" data-order=\"69\"\u003e\n\u003ctd\u003eSteel thickness – body\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/16''\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"EpAciDi\" data-order=\"70\"\u003e\n\u003ctd\u003eSteel thickness – top\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/16''\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"OuvAHi\" data-order=\"83\"\u003e\n\u003ctd\u003eFireplace opening – minimum (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e27 1\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"OuvALi\" data-order=\"84\"\u003e\n\u003ctd\u003eFireplace opening – minimum (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e31 3\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"OuvAPi\" data-order=\"85\"\u003e\n\u003ctd\u003eFireplace opening – minimum (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e22 1\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoEmUs\" data-order=\"126\"\u003e\n\u003ctd\u003eUSA standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEPA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoEmCa\" data-order=\"127\"\u003e\n\u003ctd\u003eCanadian Standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCSA B415.1-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoSeUs\" data-order=\"128\"\u003e\n\u003ctd\u003eUSA standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUL 1482, UL 737\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"NoSeCa\" data-order=\"129\"\u003e\n\u003ctd\u003eCanadian standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eULC S628\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"TestPar\" data-order=\"130\"\u003e\n\u003ctd\u003eTested and listed as per applicable standards\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBy an accredited laboratory (CAN\/USA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-spec-id=\"Garantie\" data-order=\"131\"\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLimited lifetime\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table-block site-margin no-margin-bottom\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cspan class=\"bold\"\u003eMinimum clearances to combustibles*\u003c\/span\u003e\u003cbr\u003e\u003cem\u003e(Data expressed in inches. 1 inch = 25.4 mm)\u003c\/em\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd colspan=\"1\" align=\"center\"\u003eCanada\u003c\/td\u003e\n\u003ctd colspan=\"1\" align=\"center\"\u003eUnited-States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – top (measured from the platform on which the appliance is installed)**\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – combustible side mantle to unit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e9 1\/2\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e9 1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – combustible top mantle to unit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e12\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e12\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – combustible side wall to unit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e19\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e19\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – minimum floor protection in front of the appliance\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e18\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance - from the top of the unit to the shelf\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e12\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – from the top of the insert to the shelf\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e12\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 class=\"h2 no-margin-top\"\u003eGuides\u003c\/h4\u003e\n\u003cp class=\"pdf-list\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003e\u003ca rel=\"noopener\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7559\/45999a_2024-11-01.pdf\" target=\"_blank\"\u003eOsburn Matrix 2700 wood insert install \u0026amp; owner's manual\u003cspan class=\"pdf-size\"\u003e(PDF - 7.7 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7559\/45999a_2024-11-01.pdf\"\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5186\/ob02700-osburn-matrix-2700-encastrable.pdf\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pdf-list\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5186\/ob02700-osburn-matrix-2700-encastrable.pdf\" target=\"_blank\"\u003eOsburn Matrix 2700 dimensions\u003cspan class=\"pdf-size\"\u003e(PDF - 1.1 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5186\/ob02700-osburn-matrix-2700-encastrable.pdf\"\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/6948\/46122af_2023-05-30.pdf\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pdf-list\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/6948\/46122af_2023-05-30.pdf\" target=\"_blank\"\u003eInstallation instructions | Cuttable faceplate | Projection kit\u003cspan class=\"pdf-size\"\u003e(PDF - 1.1 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/6948\/46122af_2023-05-30.pdf\"\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4 class=\"h2 no-margin-top\"\u003ePlans \u0026amp; CAD\u003c\/h4\u003e\n\u003cp class=\"pdf-list\"\u003e\u003cspan class=\"iconfont iconfont-stp\"\u003e\u003c\/span\u003e\u003ca rel=\"noopener\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5264\/ob02700.dwg\" target=\"_blank\"\u003e2D Diagrams\u003cspan class=\"pdf-size\"\u003e(DWG - 0.7 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pdf-list\"\u003e\u003cspan class=\"iconfont iconfont-stp\"\u003e\u003c\/span\u003e\u003ca rel=\"noopener\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5263\/ob02700.dxf\" target=\"_blank\"\u003e2D Diagrams\u003cspan class=\"pdf-size\"\u003e(DXF - 2.6 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Osburn","offers":[{"title":"Default Title","offer_id":51361690288430,"sku":"OB02700","price":5099.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0731\/2159\/5694\/files\/ob02700_oa10253_web.jpg?v=1764723601"},{"product_id":"stratford-ii-wood","title":"STRATFORD II Osburn Wood Fireplace","description":"\u003ch3 class=\"p-head-title\"\u003eSTRATFORD II WOOD FIREPLACE\u003c\/h3\u003e\n\u003cp\u003eLet yourself be charmed by the timeless beauty of this non-catalytic wood fireplace, which performs particularly well and meets the EPA's most restrictive emissions standards.\u003c\/p\u003e\n\u003cp\u003eThe Stratford II offers you more, including a\u003cstrong\u003e 2.5 cubic foot\u003c\/strong\u003e firebox that’s easy to access through double-cast iron doors. This unit will impress you with its distinctive style and exceptional heating capacity. \u003c\/p\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TyComb\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eHeating area :\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\"\u003e750 - 2,200 Ft\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output :\u003c\/td\u003e\n\u003ctd data-spec-id=\"PWMaSoi\"\u003e80,000 BTU\/h (23.4 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 class=\"h2\"\u003eAppliance performance\u003c\/h3\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TyComb\" colspan=\"2\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eRecommended heating area-ft² :\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\" colspan=\"2\"\u003e750 - 2,200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall firebox volume-ft³ :\u003c\/td\u003e\n\u003ctd data-spec-id=\"VolComi\" colspan=\"2\"\u003e2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eEPA loading volume-ft³ :\u003c\/td\u003e\n\u003ctd data-spec-id=\"LoadEPA\" colspan=\"2\"\u003e1.94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum burn time :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TempComb\" colspan=\"2\"\u003e8 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output-dry cordwood :\u003c\/td\u003e\n\u003ctd data-spec-id=\"PWMaSoi\" colspan=\"2\"\u003e80,000 BTU\/h (23.4 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall heat output rate \u0026lt; :\u003c\/td\u003e\n\u003ctd data-spec-id=\"PwThMin,PwThMax\" colspan=\"2\"\u003e12,700 BTU\/h (3.72 kW) to 60,700 BTU\/h (17.79 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage overall efficiency (dry cordwood) :\u003c\/td\u003e\n\u003ctd data-spec-id=\"ReMoyGBmi\"\u003e64% (HHV)\u003c\/td\u003e\n\u003ctd data-spec-id=\"RenMoyGBi\"\u003e68% (LHV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum overall efficiency :\u003c\/td\u003e\n\u003ctd data-spec-id=\"EffOpti\" colspan=\"2\"\u003e70%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum heat transfer efficiency :\u003c\/td\u003e\n\u003ctd data-spec-id=\"RenOTCi\" colspan=\"2\"\u003e68%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage particulate emissions rate :\u003c\/td\u003e\n\u003ctd data-spec-id=\"Emiss\" colspan=\"2\"\u003e1.2 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage CO :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TauxCO\" colspan=\"2\"\u003e98 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 class=\"h2 no-margin-top\"\u003eGuides\u003c\/h3\u003e\n\u003cp class=\"pdf-list\"\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7612\/46104a_2024-12-18.pdf\" class=\"pdf-list-link\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eStratford II wood fireplace install \u0026amp; owner's manual\u003cspan class=\"pdf-size\"\u003e(PDF - 8.6 Mo)\u003c\/span\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pdf-list\"\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5240\/ob04007-osburn-stratford-ii.pdf\" class=\"pdf-list-link\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eStratford II dimensions\u003cspan class=\"pdf-size\"\u003e(PDF - 1.4 Mo)\u003c\/span\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5238\/stratford-ii_en_quick-install-reference-guide.pdf\" class=\"pdf-list-link\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pdf-list\"\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5238\/stratford-ii_en_quick-install-reference-guide.pdf\" class=\"pdf-list-link\" target=\"_blank\" rel=\"noopener\"\u003eStratford II wood fireplace quick install reference guide\u003cspan class=\"pdf-size\"\u003e(PDF - 0.6 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pdf-list\"\u003e\u003ca href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7334\/46337af_2024-01-15.pdf\" class=\"pdf-list-link\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eInstallation instructions for faceplates OA10255 and OA10256\u003cspan class=\"pdf-size\"\u003e(PDF - 0.5 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Osburn","offers":[{"title":"Default Title","offer_id":51453296673070,"sku":"OB04007","price":5699.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0731\/2159\/5694\/files\/ob04007_oa10255_oa10610_web.jpg?v=1765672175"},{"product_id":"everest-iii-wood","title":"EVEREST III Osburn Wood Fireplace","description":"\u003ch3 class=\"p-head-title\"\u003eEVEREST III WOOD FIREPLACE\u003c\/h3\u003e\n\u003cp\u003eThe Everest III combines authentic warmth and proven performance, offering a heating solution designed for your daily comfort. Versatile and efficient, this wood fireplace transforms your home into a cozy nook, perfect for braving the harshest winter days.\u003c\/p\u003e\n\u003cp\u003eThe cast iron retractable doors of the Everest III stand out for their versatility, perfectly suited to your needs. When closed, this fireplace optimizes combustion for efficient and long-lasting heat. When open, with an optional firescreen (available as an option – AC01226), you can safely enjoy the ambiance and crackling sound of the flames.\u003c\/p\u003e\n\u003cp\u003eThe high-efficiency Everest III fireplace is designed to maximize heat output while minimizing emissions, meeting the strictest environmental standards. Capable of heating up to 2,500 square feet, it serves as an ideal alternative heat source for your home.\u003c\/p\u003e\n\u003cp\u003eCarefully crafted in Canada, this non-catalytic wood fireplace is distinguished by the quality of its design and durable materials. Available with a timeless black or brushed silver door finish, the Everest III seamlessly blends into any decor while adding a touch of refinement.\u003c\/p\u003e\n\u003cp\u003eWith the Everest III, enjoy the authentic warmth and ambiance of wood heating, while benefiting from a high-performance unit designed to maximize your comfort.\u003c\/p\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TyComb\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eHeating area :\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\"\u003e750 - 2,500 Ft\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output-dry cordwood :\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-fireplaces\/everest-iii-wood-fireplace\/#note-order-1\" data-target-tab=\"fiche-technique\"\u003e1\u003c\/a\u003e)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd data-spec-id=\"PWMaSoi\"\u003e85,000 BTU\/h (24.9 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 class=\"h2\"\u003eAppliance performance\u003c\/h3\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TyComb\" colspan=\"2\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eRecommended heating area-ft² :\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\" colspan=\"2\"\u003e750 - 2,500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall firebox volume-ft³ :\u003c\/td\u003e\n\u003ctd data-spec-id=\"VolComi\" colspan=\"2\"\u003e3.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eEPA loading volume-ft³ :\u003c\/td\u003e\n\u003ctd data-spec-id=\"LoadEPA\" colspan=\"2\"\u003e2.61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum burn time :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TempComb\" colspan=\"2\"\u003e8 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output-dry cordwood :\u003c\/td\u003e\n\u003ctd data-spec-id=\"PWMaSoi\" colspan=\"2\"\u003e85,000 BTU\/h (24.9 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall heat output rate \u0026lt; :\u003c\/td\u003e\n\u003ctd data-spec-id=\"PwThMin,PwThMax\" colspan=\"2\"\u003e25,900 BTU\/h (7.6 kW) to 78,200 BTU\/h (22.9 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage overall efficiency (dry cordwood) :\u003c\/td\u003e\n\u003ctd data-spec-id=\"ReMoyGBmi\"\u003e65% (HHV)\u003c\/td\u003e\n\u003ctd data-spec-id=\"RenMoyGBi\"\u003e(LHV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum overall efficiency :\u003c\/td\u003e\n\u003ctd data-spec-id=\"EffOpti\" colspan=\"2\"\u003e71.6%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum heat transfer efficiency :\u003c\/td\u003e\n\u003ctd data-spec-id=\"RenOTCi\" colspan=\"2\"\u003e68%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage particulate emissions rate :\u003c\/td\u003e\n\u003ctd data-spec-id=\"Emiss\" colspan=\"2\"\u003e1.9 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage CO :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TauxCO\" colspan=\"2\"\u003e1.7 g\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 class=\"h2 no-margin-top\"\u003eGuides\u003c\/h3\u003e\n\u003cp class=\"pdf-list\"\u003e\u003ca rel=\"noopener\" class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7590\/46401ia_2024-11-25.pdf\" target=\"_blank\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eEverest III wood fireplace install \u0026amp; owner's manual\u003cspan class=\"pdf-size\"\u003e(PDF - 7.7 Mo)\u003c\/span\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7592\/ob04017-everest-iii.pdf\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pdf-list\"\u003e\u003ca rel=\"noopener\" class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7592\/ob04017-everest-iii.pdf\" target=\"_blank\"\u003eEverest III dimensions\u003cspan class=\"pdf-size\"\u003e(PDF - 0.4 Mo)\u003c\/span\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pdf-list\"\u003e\u003ca rel=\"noopener\" class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7658\/46239u_a_2024-11-19.pdf\" target=\"_blank\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eWood fireplace manual | Safety notifications \u0026amp; general information\u003cspan class=\"pdf-size\"\u003e(PDF - 2.7 Mo)\u003c\/span\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pdf-list\"\u003e\u003ca rel=\"noopener\" class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7857\/46357af_2024-01-15.pdf\" target=\"_blank\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eFaceplates installation instructions\u003cspan class=\"pdf-size\"\u003e(PDF - 0.5 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Osburn","offers":[{"title":"Default Title","offer_id":51453561536814,"sku":"OB04017","price":6399.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0731\/2159\/5694\/files\/ob04017_oa10623_oa10620_web.jpg?v=1765672767"},{"product_id":"horizon-wood","title":"HORIZON Osburn Wood Fireplace","description":"\u003ch3 class=\"p-head-title\"\u003eHORIZON WOOD FIREPLACE\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBeyond the Size!\u003cbr\u003e\u003c\/strong\u003eThis wood fireplace offers peace of mind due to the combination of energy efficiency and clean heating. A simple solution; its clean design suits any type of decor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLarge fireplace.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBehind its large glass door, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4.28 cubic foot\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecombustion chamber can hold an impressive\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e60 lbs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof wood.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLow emissions.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis energy efficient fireplace complies with the EPA’s clean-air standards (only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1.6 g\/hr\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof emissions) in particular through the intelligent air control mechanism is a patented design that optimizes combustion quality.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh efficiency.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe Horizon fireplace is capable of heating large spaces and burns for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e11 hours.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TyComb\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eHeating area :\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\"\u003e1,000 - 2,800 Ft\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output :\u003c\/td\u003e\n\u003ctd data-spec-id=\"PWMaSoi\"\u003e95,000 BTU\/h (27.8 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 class=\"h2\"\u003eAppliance performance\u003c\/h3\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TyComb\" colspan=\"2\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eRecommended heating area-ft² :\u003c\/td\u003e\n\u003ctd data-spec-id=\"Surfi\" colspan=\"2\"\u003e1,000 - 2,800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall firebox volume-ft³ :\u003c\/td\u003e\n\u003ctd data-spec-id=\"VolComi\" colspan=\"2\"\u003e4.28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eEPA loading volume-ft³ :\u003c\/td\u003e\n\u003ctd data-spec-id=\"LoadEPA\" colspan=\"2\"\u003e4.28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum burn time :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TempComb\" colspan=\"2\"\u003e11 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output-dry cordwood :\u003c\/td\u003e\n\u003ctd data-spec-id=\"PWMaSoi\" colspan=\"2\"\u003e95,000 BTU\/h (27.8 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall heat output rate \u0026lt; :\u003c\/td\u003e\n\u003ctd data-spec-id=\"PwThMin,PwThMax\" colspan=\"2\"\u003e16,900 BTU\/h (5.0 kW) to 43,000 BTU\/h (12.6 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage overall efficiency (dry cordwood) :\u003c\/td\u003e\n\u003ctd data-spec-id=\"ReMoyGBmi\"\u003e64 % (HHV)\u003c\/td\u003e\n\u003ctd data-spec-id=\"RenMoyGBi\"\u003e69 % (LHV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum efficiency :\u003c\/td\u003e\n\u003ctd data-spec-id=\"EffOpti\" colspan=\"2\"\u003e70 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum heat transfer efficiency :\u003c\/td\u003e\n\u003ctd data-spec-id=\"RenOTCi\" colspan=\"2\"\u003e69 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage particulate emissions rate :\u003c\/td\u003e\n\u003ctd data-spec-id=\"Emiss\" colspan=\"2\"\u003e1.6 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage CO :\u003c\/td\u003e\n\u003ctd data-spec-id=\"TauxCO\" colspan=\"2\"\u003e159.0 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 class=\"h2 no-margin-top\"\u003eGuides\u003c\/h3\u003e\n\u003cp class=\"pdf-list\"\u003e\u003ca rel=\"noopener\" class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/3915\/45857a_2025-01-27.pdf\" target=\"_blank\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eHorizon wood fireplace install \u0026amp; owner's manual\u003cspan class=\"pdf-size\"\u003e(PDF - 16.9 Mo)\u003c\/span\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pdf-list\"\u003e\u003ca rel=\"noopener\" class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/2976\/ob04010-horizon.pdf\" target=\"_blank\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003eHorizon dimensions\u003cspan class=\"pdf-size\"\u003e(PDF - 0.3 Mo)\u003c\/span\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/4398\/horizon-quick-install-reference-guide.pdf\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pdf-list\"\u003e\u003ca rel=\"noopener\" class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/4398\/horizon-quick-install-reference-guide.pdf\" target=\"_blank\"\u003eHorizon wood fireplace quick install reference guide\u003cspan class=\"pdf-size\"\u003e(PDF - 0.6 Mo)\u003c\/span\u003e\u003cspan class=\"iconfont iconfont-download\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7340\/46361af_2024-01-15.pdf\"\u003e\u003cspan class=\"iconfont iconfont-pdf\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pdf-list\"\u003e\u003ca rel=\"noopener\" class=\"pdf-list-link\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7340\/46361af_2024-01-15.pdf\" target=\"_blank\"\u003eFaceplate Installation Instructions\u003cspan class=\"pdf-size\"\u003e(PDF - 0.5 Mo)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Osburn","offers":[{"title":"Default Title","offer_id":51453657055534,"sku":"OB04010","price":7499.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0731\/2159\/5694\/files\/ob04010-horizon_h1.jpg?v=1772405953"}],"url":"https:\/\/mhchomecomfort.com\/collections\/osburn.oembed","provider":"Fireplace store Mississauga","version":"1.0","type":"link"}